Sterling 882.000254.00 Benutzerhandbuch

Seite von 91
7/50D Plus or 7/50D Controller 
Chapter 4: Operation 
56 
The following table explains the status represented by each color at the Station Summary 
screen. 
Color Label 
Description 
Gray outline 
Offline 
Station is not enabled. The controller ignores any demands or 
alarms. 
Blue 
Ready 
Station is enabled and idle (full). 
Yellow 
Demand 
Station requires material. 
Green 
Loading 
Station is being loaded with material or is dumping material into 
its receiver. 
White 
Purging 
The material line is being purged of material. 
Light Blue 
Dumping 
The station is dumping material into its receiver. 
Blue, blinking 
Blow Back 
Station’s air filter is being cleaned by blowing compressed air 
backward through it. 
Black, blinking 
Bypass 
Bypass switch at the station has been turned on, disabling the 
station. 
Green, blinking 
Priority 
Station is in priority convey mode. Its pump will be temporarily 
dedicated to filling it as soon as possible. 
Red, blinking 
Alarm 
Station is in alarm. 
Red outline, blinking 
Critical 
Station is in critical alarm. The controller has disabled the station 
until the alarm is cleared. 
 
Additional basic information about each station (convey time, dump delay, pump assignment, 
and, if enabled, RPV setting, purge settings, and material proofing) is available at the Station 
n Operator screen. See p. 61 for details. 
Detailed configuration settings for each station are available at the Station n Setup screen. See 
p. 74 for details.