National Instruments PXI-1006 User Manual Benutzerhandbuch

Seite von 46
Appendix A
Specifications
A-2
ni.com
DC Output
Maximum usable power .........................600 W
DC current capacity (I
MP
)
Load regulation
Maximum ripple and noise .....................1% ripple, 1% noise
20 MHz bandwidth
Over-current protection...........................105–140% of rated output
current; automatic recovery
Over-voltage protection ..........................3.3 V, 5 V clamp at 122–134%
of output voltage
+12 V and –12 V clamp at
110–120% of output voltage
Power supply/fan unit MTTR .................Replacement in under 5 minutes
Cooling
Module cooling system...........................Forced air circulation
(positive pressurization) via
three 140 cfm fans with
HI/AUTO speed selector
Voltage
I
MP
(Steady-State Current)
+3.3 V
60 A
+5 V
60 A
+12 V
9 A
–12 V
1.8 A
Voltage
Regulation
+3.3 V
0.4% or 20 mV max
+12 V
0.4% or 20 mV max
+5 V
0.4% or 20 mV max
–12 V
0.4% or 20 mV max