National Instruments PXI-1006 User Manual Benutzerhandbuch
© National Instruments Corporation
A-1
A
Specifications
This appendix contains specifications for the PXI-1006 chassis.
Electrical
AC Input
Input voltage range................................. 90–264 VAC
Input frequency range ............................ 47 to 63 Hz
Over-current protection .......................... 10 A circuit breaker
Maximum steady state
operating current .................................... 10 A
operating current .................................... 10 A
Line regulation ....................................... ± 0.1% over operating line range
Efficiency ............................................... 70-80% typical
Power disconnect ................................... The (standby) power switch
causes the power module to
supply DC power to
the CompactPCI/PXI backplane.
The rear-panel D-sub connector
facilitates remote inhibiting
operation. The (standby) switch
must be in the On position prior to
use of remote inhibit. The power
cord provides main power
disconnect.
supply DC power to
the CompactPCI/PXI backplane.
The rear-panel D-sub connector
facilitates remote inhibiting
operation. The (standby) switch
must be in the On position prior to
use of remote inhibit. The power
cord provides main power
disconnect.