Issue  2   April 1996
6-11
Connectivity
To Program PBX Ports
To Program PBX Ports
When to use
Program the ports for the DEFINITY G3r and G3i PBXs after you 
have established the port terminations. 
Guidelines 
Use the following guidelines when you program ports:
On DEFINITY G3r, the system port requires a data board 
and pdata board. 
On DEFINITY G3i, use the following commands:
Procedural 
overview
Use the following procedures to program DEFINITY G3i and G3r 
PBXs for compatibility with the Proxy Agent: 
Use this 
command ...
To do this ...
add data-module
Assign the type netcon to an 
extension
add hunt-group
Ad d the netcon extension as a 
member of a hunt group