Honeywell W8735B Benutzerhandbuch

Seite von 12
TELEPHONE ACCESS MODULE
69-1352
10
Receiving and Acknowledging an Alert 
Message
The W8735B dials out until someone answering the 
telephone (at the dial-out telephone number setting 
locations described in Configuration No. 9 in Table 3) 
acknowledges the alert message. 
The message is acknowledged by pressing 1 on the 
telephone keypad. If there is no acknowledgement, the 
W8735B continues to dial the first two telephone 
numbers in sequence every 30 minutes until an 
acknowledgement is received. 
The third telephone number setting is designed to enable 
the HVAC contractor to provide a monitoring service at 
the homeowner’s request. If a telephone number was 
programmed into the third telephone location, the 
W8735B also dials the third number and continues until 
the HVAC contractor acknowledges the alert.
NOTE:
The W8735B considers telephone number set-
tings one and two independently from telephone 
number setting three. Even when the recipient 
at telephone number setting one or two 
acknowledges the alert, it dials out and attempts 
to receive an acknowledgement from the recipi-
ent at telephone number three, and vice-versa.
When the homeowner dials in and is informed that an 
alert is active, the alert can be acknowledged 
immediately to stop the calls to telephone numbers 
settings one and two but not to telephone number setting 
three. 
IMPORTANT
Only the HVAC contractor can acknowledge the 
alert dialed to telephone number setting three.
The HVAC contractor dials in to cancel the active alert 
messages to telephone number setting three by:
Calling the home, 
Entering the last five digits of the telephone number 
setting three as the pass code; for example, if the 
telephone number is 555-1234, entering 5 1 2 3 4 as 
the pass code, and
Following the menu to clear the alerts. (Using this 
pass code allows only the HVAC dealer to cancel the 
dial-out alert messages to telephone number setting 
three.)
Sending an Alert Message
The W8735B can initiate a dial-out sequence from the 
conditions in Table 5.
Table 4. Zone IDs.
Zone ID 
No.
Zone Name
1
Basement
2
Bathroom
3
Bedroom
4
Den
5
Dining Room
6
Foyer
7
Game Room
8
Great  Room
9
Guest Room
10
Gym
11
Kid’s Bedroom
12
Kitchen
13
Library
14
Lower Level
15
Master Bedroom
16
Media Room
17
Nursery
18
Office
19
Pool Room
20
Porch
21
Spa
22
Sunroom
23
Theater
24
Upper Level
25
Wine Cellar
26
Workshop