TELEPHONE ACCESS MODULE
69-1352
4
Wiring the Telephone
CAUTION
Incorrect Telephone Line Hookup Hazard.
Inability to call out can result in personal 
injury or property damage.
Improper installation can result in blocked 
phone lines and inability to make 911 and 
other emergency-reporting phone calls.
Always connect the Telephone Access Module 
first in line. When a monitored security system is 
installed, connect the Telephone Access Module 
second in line. 
Observing this practice ensures that Telephone 
Access Module drops off the line to allow priority 
to the house telephone.
1.
Wire the telephone line from the telephone com-
pany to the Line in connections on the Telephone 
Access Module.
IMPORTANT:
Wiring the Telephone Access Module first in line 
(or second in line with a monitored security sys-
tem) ensures that when any house telephone is 
used (such as for an emergency), the Tele-
phone Access Module drops off the line and 
gives control priority to the house telephone.
2.
Wire the house telephones to the Phone out con-
nections (see Table 2) on the Telephone Access 
Module.
3.
After the Telephone Access Module installation is 
complete, be sure to verify that the emergency 
telephone line disconnect is operating correctly. 
a. Call the Telephone Access Module using an 
outside line (installers use a cell phone).
b. While calling into the Telephone Access Mod-
ule, pick up a house telephone receiver. If you 
get a dial tone after a few seconds and the 
Telephone Access Module drops control of the 
line, the Telephone Access Module is installed 
correctly.
c. If you do not get a dial tone on the house tele-
phone, follow the wiring diagrams and rewire 
the telephone connections. See Fig. 8 and 9.
IMPORTANT:
Do not leave the installation until the emergency 
telephone line disconnect is operating correctly. 
a
Connect to 
either 
Line in or use terminals Ln1 and Ln2.
b
Connect to 
either 
Phone out or use terminals Ph1 and Ph2.
Wiring Diagrams
See Fig. 7 through 9 for wiring diagrams.
Table 2. Terminal Designations.
W8735B Terminal Designations
Function
1
To EnviraCom network terminal 1 (data).
2
To EnviraCom network terminal 2 (24 Vac).
3
To EnviraCom network terminal 3 (24 Vac).
Aux1
Auxiliary Input – Connect to N.O. sensor contact.
Aux2
Auxiliary Input – Connect to N.O. sensor contact.
Line in
a
RJ11 connector – Connect to telephone line.
Phone out
b
RJ11 connector – Connect to home telephones
Ln1
Line in - Connect to telephone line.
Ln2
Line in - Connect to telephone line.
Ph1
Phone out - Connect to home telephones.
Ph2
Phone out - Connect to home telephones.