Approach Tech DVR-3024 Benutzerhandbuch

Seite von 71
 
35
RECORD
ALARM / MOTION
CLOCK/ TIMER
COMMUNICATION
DISK
SYSTEM  
                 
MAIN  MENU
GOTO COMM PAGE 
 
 
 
 
 
 
 
 
 
 
 
 
COMM ID:   
Communication ID is for RS232 and RS485 
communication. After the DVR
 
receives a 
RS232 or RS485 command, it checks if the 
<Dest ID> within the code is the same as the 
COMM ID, in which case the particular 
command can be accepted. 
 
RS-232:  
The RS-232 communication port can be 
either in an importing or exporting mode 
according to your applications. 
ON: Enables the RS-232 communication 
port. When you wish the unit to be 
controlled by an external device, 
please select this entry for use. 
OFF: Disables the RS-232 communication 
port. 
 
RS-485:  
The RS-485 communication port can be 
either in an importing or exporting mode 
according to your applications. 
ON: Enables the RS-485 communication port. 
When you wish the unit to be controlled 
by an external device, please select this 
entry for use. 
OFF: Disables the RS-485 communication 
port. 
BAUD: 
You have the option of using a Baud rate ( at 
8 different levels : 24004800960019200, 
2880038400, 57600 or 115200). 
 
NET ENABLE:   
This option selects either enable or disable for 
the Ethernet communication port. 
OFF: Disables  it.   
ON: Enables it. 
 
NET DHCP:   
This option selects enable or disable for the 
DHCP communication function. 
OFF: Disables  it.   
ON: Enables it. 
 
NOTE: If provided with a DHCP server, the DVR 
can get an IP automatically by setting this option 
to ON.   
 
NET IP:   
This option is used to configure the Ethernet 
communication settings. This is required for 
the purpose of making a network connection. 
Please consult with a qualified MIS 
professional to configure it.   
IP:   
        XXX.XXX.XXX.XXX 
MASK: 
        XXX.XXX.XXX.XXX   
GATEWAY:   XXX.XXX.XXX.XXX 
HTTP PORT:    XXXX 
 
FTP SETTING:   
This entry allows users to set the FTP File 
Transfer Protocol.   
 
 
 
 
 
 
 
 
COMM SETTING
 
COMM ID 
:01 
RS232 :ON 
RS485 :ON 
BAUD :2400 
NET ENABLE 
:OFF 
NET DHCP 
:OFF 
NET IP 
:SET 
NET ACCOUNT 
:SET 
FTP SETTING 
 
MAIN PAGE 
COMM SETTING 
 
COMM ID 
:01 
RS232 :ON 
RS485 :ON 
BAUD :2400
NET ENABLE 
:OFF
NET DHCP 
:OFF
NET IP 
:SET
NET ACCOUNT 
:SET
FTP SETTING 
 
 
MAIN PAGE