TIME COMMANDS
The DGy 201x recorder uses an internal real time clock to time stamp 
recordings. This clock can be set manually or can be synchronized 
automatically on a periodic basis to an external time reference. DGy 
201x
 supports the use of a Network Time Server (using the NTP 
protocol) or as an option may be connected to an IRIG-B time standard.
Table 6-9  
Time Commands  
Command
Arguments
Description
CurrentTIME
[RAW]
Displays currently computed local time of DGy 
internal clock with the date in mm/dd/yyyy 
format and time displayed in hh:mm:ss format. 
The time displayed is the current local time. If 
the time zone is changed the local time will 
also be changed.
To display the time as an unformatted data 
string use the optional RAW argument. For 
example if the current date and time are 3/02/
2005 8:01:23, then using the RAW argument 
DGy will respond with the string 
2005302080123.
RealTimeClockSET
<yyyymmddhhmmss>
Sets the internal DGy real time clock. This 
should only be used if no other method of 
timesetting is available.
TimeZone
<-12 ... +12>
Sets the timezone relative to UTC, For 
example Pacific Standard Time (PSRT) is -8 (8 
hours behind UTC). DGy must be rebooted 
before the new time zone takes effect.
IRIGMaster
<ON | OFF>
Configures the IRIG output circuitry. When ON, 
an IRIG-B timecodes in the DCLS format will 
be generated on the output based on the 
current time on the DGy. When OFF, the output 
will be a loop of the input.
IRIGSTandarD
[DCLS | MOD1K]
The IRIGSTD command is used to set the 
optional IRIG-B (format B123) input to accept 
either a DCLS (DC Level shift) or MOD1K 
(modulated 1kHz) reference signal.
Default: DCLS
NTSIP 
[Network Time Server IP 
address]
Sets the IP address of a Network Time Server. 
Up to three IP addresses can be set.
See also the commands: 