O P E R A T I O N
Options Window
350-9047 v3.0.1
DGy Model 201x User’s Guide
51
. . . . .
To return to autosync for RGB again select 
RGB
 for 
Video Input
. Input 
video Autosync is restored.
C R E A T I N G   A   N E W   T I M I N G   E N T R Y
If there is no entry in the timing list that matches a specific signal, a new 
one can be created. Find an entry in the list that is very close to the 
required parameters. Load the entry, modify it, and then save the new 
entry to the user defined timing list. There are over 100 available user 
entries.
Use the following procedure to create a new (user defined) entry in the 
timing list:
Click the Edit button in the Input Timing section of the Input 
Timing
 page.
Enter new timing parameters into each of the timing parameter 
boxes.
Scroll to an empty timing list number above #100 in the Timing 
List
 entry box.
Click the SAVE button.
A dialog box will open allowing you to name the new entry.
Enter a name for the new timing entry and click OK.
The name can be up to 23 characters in length and can contain 
upper and lower and numeric characters. Avoid the use of a 