RGB Spectrum 201 Benutzerhandbuch

Seite von 167
C O M M A N D   L I N E   I N T E R F A C E
Command Summary
350-8697
DGy Model 201 User Guide
120
. . . . .
T I M E   C O M M A N D   D E S C R I P T I O N S
The DGy 201 recorder uses an internal real time clock to time stamp 
recordings. This clock can be set manually or can be synchronized 
automatically on a periodic basis to an external time reference. DGy 201 
supports the use of a Network Time Server (using the NTP protocol) or 
as an option may be connected to an IRIG-B time standard.
Table 6-13.  
Time Commands
Command
Arguments
Description
CurrentTIME
[RAW]
Displays currently computed local time of DGy 
internal clock with the date in mm/dd/yyyy format 
and time displayed in hh:mm:ss format. The time 
displayed is the current local time. If the time 
zone is changed the local time will also be 
changed.
To display the time as an unformatted data string 
use the optional RAW argument. For example if 
the current date and time are 3/02/2005 8:01:23, 
then using the RAW argument DGy will respond 
with the string 2005302080123.
RealTimeClockSET
<yyyymmddhhmmss>
Sets the internal DGy real time clock. This should 
only be used if no other method of timesetting is 
available.
TimeZone
<-12 ... +12>
Sets the timezone relative to UTC, For example 
Pacific Standard Time (PSRT) is -8 (8 hours 
behind UTC). DGy must be rebooted before the 
new time zone takes effect.
IRIGSTandarD
[DCLS | MOD1K]
The IRIGSTandard command is used to set the 
optional IRIG-B (format B123) input to accept 
either a DCLS (DC Level shift) or MOD1K 
(modulated 1kHz) reference signal.
Factory default: DCLS
NTSIP 
{Network Time Server 
IP address}
Sets the IP address of a Network Time Server. Up 
to three IP addresses can be set.
See also the commands: 
and