9  SUBNET MASK : Input the [SUBNET MASK] address obtained from the internet service 
company of  the user. 
9  GATEWAY : Input the [GATEWAY] address obtained from the internet service company of  
the user. 
9  DNS : Input the [DNS] address obtained from the internet service company of  the user. 
9  PORT : [PORT] assigned when connecting to a computer can be changed. If  port is changed 
in the DVR, When the network setup is changed, it takes time to setup the network module 
again. Connect after 1~2 minutes. Port number can be setup depending on network 
conditions (firewall etc.). 
DEFAULT PORT : 4000 
9  SWR : If  the product is connected to a cable modem or a xDSL modem, IP    address will 
change each time connection to ISP (User’s communicaton company server) is attempted. In 
this case, the user will not know the changed IP address. If  a product using a floating    IP is 
registered on the SWR server, the changed IP can be found when attempting connection with 
the product. To register an IP    address on the SWR, setup [SWR] item to ON. Changed IP 
address can be verified from FUNCTION-STATUS (SYSTEM INFORMATION 2). 
 
5.9.2 RS-232 
Setup items needed to connect with the computer connected to the product through the serial port. 
 
 
9  BAUD RATE : Setup the data transmission speed per second. 
9  DATA BIT : Setup the data transmission bit. 
9  PARITY BIT : Setup the error check method for data transmission. 
9  STOP BIT : Setup bit to include when data transmission has been completed.