Samsung DVR-16TH Benutzerhandbuch

Seite von 175
User’s Manual 
DVR-4TH/8TH/16TH Series 
SPECO TECHNOLOGIES 07/10
 
112 
Use the Direction keys to move the cursor and press ENTER to enable or 
disable a grid. Press MODE to select all of the grids for detection; press 
MODE again to de-select all of the grids. 
 
 Sensitivity 
This item is used to set the sensitivity of detection grids for the camera. A 
greater value indicates more sensitive motion detection. A motion alarm will 
be triggered, once the amount of motion detected exceeds the Threshold 
value 
 
Move the cursor to <Sensitivity> and press ENTER, and then use UP / 
DOWN keys to adjust the value. The value is indicated in 4% increment. 
 
 Area 
Threshold 
<Area Threshold> means the motion alarm triggered level; if the percentage 
of triggered grids to total detection area is greater than the set value, the 
motion alarm will be triggered.   
 
For example, if 10 grids are selected and the < Area Threshold > value is 70%, 
the motion alarm will be triggered when 7 grids are motion detected. 
 
Move the cursor to < Area Threshold > and press ENTER, then use UP / 
DOWN keys to adjust the value. The value is indicated in 1% increments. 
 
 
5.6.8.5   Alarm In 
This item allows the user to enable / disable alarm input detection. According 
to your application, select <N/O> (Normal Open) or <N/C> (Normal Close) to 
enable the alarm input detection or select <OFF> to disable detection. The 
default setting is <OFF>.   
 
NOTE: If you set this item to <N/C> but did not install any device to the unit, 
the alarm will be triggered and the Event Icon will be displayed continually 
until this item is changed to <N/O>, <OFF> or, install a device to the unit. 
 
5.6.8.6   Alarm Out 
This item allows the user to assign an alarm on a certain channel to activate 
the relays. These signals can be used to drive a light or siren to caution an 
alarm event.