Toshiba XVR4-120-X Benutzerhandbuch
44
ALARM SETUP
The Sensor and Output Window allows you to enable, disable and configure Sensors and Control Outputs.
1
Type
Selects whether the Sensor will be Normally Open (NO) or Normally Closed (NC).
2
Delay
Adjusts the amount of time (in seconds) to ignore the sensor if it is continuously activated.
3
Relay
Selects the Control Output to activate once the Sensor has been tripped. Users can
select multiple Control Outputs by placing a comma between numbers.
select multiple Control Outputs by placing a comma between numbers.
4
Onscreen Keyboard
Clicking this button brings up an onscreen keyboard.
5
Hybrid Sensor Setup
Allows users to configure Hybrid (IP) Sensors (requires a software upgrade)
6
Sensor Preset
Allows users to create and name sensor presets.