Troubleshooting 
Page 6-28
Calls From a Remote System Do Not Reach the Centralized Voice Messaging 
6
If the routing is correct and enough routes are included in the pattern, but 
the problem persists, check if PRI lines are used. If they are, check the 
error log for D-channel inoperative and loss of signal alarms indicating lines 
are inoperative. If the D-channel inoperative alarm has occurred, check the 
CSU/DSU associated with the line for correct programming. If the loss at 
signal alarm has occurred, check for open cables, etc. If these conditions 
are not present, go to Possible Cause 4.
Possible Cause 4: Not enough trunks are assigned to the pools for UDP routes. 
What to Do: Check the error log for no trunks in pool (such as 4c01, Pool empty). 
If error is present, consult System Form 2c, System Numbering: Line/Trunk Jacks 
to determine the assignments. To see a report of pool assignments, select the 
3ULQW
 option on the System Programming menu and then choose
7UXQN,QIR
and
*HQHUDO
.
If more trunks are available and need to be assigned, follow the procedure 
in “Trunks to Pools Assignment” in Chapter 4 of 
System Programming to 
assign more tandem trunks. All the tandem trunks in a pool must be of the 
same type (tie or PRI). 
If not enough trunks are available, consider adding more to your system. 
If there are sufficient trunks assigned but the problem persists, go to 
Possible Cause 5.
Possible Cause 5: No Touch-Tone Receivers (TTRs) available at remote system 
when using tie trunks. 
What to Do: This can be verified by checking for the 0C03 error on the error log 
on the remote switches. 
If this error persists, contact your local service representative. 
Possible Cause 6: The Switch Type setting at both ends of a tandem PRI facility 
may match.
What to Do: The coordinating system manager must check the programmed 
Switch Type settings at networked systems. Calls are not routed properly unless 
the Switch Type setting is correctly programmed at the systems on both ends of 
any tandem PRI facilities on the call route. If only MERLIN LEGEND 
Communications Systems are included in the routing, the switch types must not 
match in a single private network link. For example, if System A is connected to 
System B by tandem PRI trunks, System A can be set to a switch type LEGEND-
PBX and System B can be LEGEND-Ntwk. It does not matter which system is 
assigned a given switch type as long as they are not the same.
If the call is routed over a tandem PRI facility connected to your system, 
ensure that the system at the other end of the facility is programmed 
correctly to work with your own setting. Consult system Non-Local UDP 
Administration Form in the Installation Specification. To see a a report 
including the switch type programmed for PRI facilities on your system, 
select the 
3ULQW
 option on the System Programming menu and then 
choose
35,,QIR
 provides summary