Lucent Technologies 555-661-150 Benutzerhandbuch

Seite von 360
MERLIN LEGEND Communications System Release 6.1
Network Reference  
555-661-150  
Issue 1
August 1998
Call-Handling Scenarios 
Page 2-4
Networking Guidelines 
2
MERLIN LEGEND Communications System extension in a private 
network. Although the MERLIN LEGEND Communications System can be 
programmed to drop digit(s), it is recommended that in networks with 
DEFINITY ECS or DEFINITY ProLogix Solutions use 4-digit dial plans. The 
next topic provides additional details.
When planning non-local extension ranges, Primary Rate Interface (PRI) 
dial-plan routing and Direct Inward Dialing (DID) numbers must be 
considered. If calls are routed across the private network to these 
numbers, they also must not conflict with extension ranges in other private 
network systems. In addition, UDP routes must specify correct digit 
manipulation (deleting or adding digits). When such calls are routed to 
5-digit DEFINITY ECS or DEFINITY ProLogix Solutions systems, special 
considerations apply. See the next topic for details.
A centralized VMS/AA is subject to the following configuration 
requirements and constraints:
— A DEFINITY ECS or DEFINITY Prologix 
cannot share a centralized 
VMS/AA with a MERLIN LEGEND system.
— The hub system and all remote systems sharing a centralized VMS/AA 
must be MERLIN LEGEND Release 6.1 or later systems.
— Each MERLIN LEGEND system must be configured as Hybrid/PBX.
— Networked MERLIN LEGEND systems that are not directly connected to 
the “hub” system (more than one span away) cannot share the 
centralized VMS/AA.
— More than one centralized VMS/AA can be configured in a single private 
network. More than one centralized VMS/AA can be installed on a single 
MERLIN LEGEND system. 
— Any MERLIN LEGEND system may also have a local VMS/AA system 
that is not shared.
— Each extension in the system can have only one voice mailbox, no 
matter how many VMS/AA systems are available.
— Only the following voice messaging systems are supported for 
centralized VMS/AA:
MERLIN LEGEND Mail
Messaging 2000
Intuity AUDIX
IS-III AUDIX Voice Power (no longer orderable)
— A Uniform Dial Plan (UDP) must be established for the private network.
— All trunks within the private network should have unique trunk numbers. 
This allows the centralized VMS/AA to provide different call handling 
and/or greetings based on the trunk on which the call was received.