To prevent exposure to RF energy, which may be 
harmful to people who stand within 36 feet 
(11 meters) of the antenna, you can configure up 
to two RF radiation hazard zones for areas where 
crew and/or passengers frequent (see Figure 41). 
The system will disable the transmitter whenever 
the antenna is pointing within one of these zones.
Follow these steps to set up an RF hazard zone.
a. Determine the necessary azimuth range for 
the RF hazard zone(s). You will need to enter, 
in clockwise order, beginning and ending 
azimuths (>4° apart) relative to the antenna’s 
forward arrow, which should be pointing 
toward the bow (see Figure 42).
b. At the control unit, press MENUS until the 
display shows “CONFIGURATION.” Then 
press ACCEPT.
c. Press MENUS until the display shows “SET 
HAZARD ZONE.”
d. Press CHANGE until the display shows “SET 
HAZARD ZONE = YES.” Then press 
ACCEPT.
e. At “ZONE 1,” press CHANGE. A cursor 
appears under the first number in the 
azimuth range for RF hazard zone #1.
f. Press CHANGE until the number is set to the 
first digit of the beginning azimuth for the 
first hazard zone.
g. Press ACCEPT. The cursor moves to the next 
number.
h. Repeat steps f and g to set the remaining 
digits of the desired RF radiation hazard 
zone. Then press ACCEPT.
i. At “Zone 2,” repeat steps e-h to set the range 
for the second RF hazard zone, if desired.
j. At “XMT IN ZONES,” verify that the display 
shows “XMT IN ZONES = NO.” Then press 
MENUS.
k. Press EXIT to exit the menu.
NOTE: For more details, refer to the Configuration 
section of the User’s Guide.
335
025
Antenna
RF Radiation
Hazard Zone
Figure 41:  Example of an RF Radiation Hazard Zone
Antenna
000
180
090
270
045
135
225
315
Forward
335
025
RF Radiation
Hazard Zone
(Example)
Beginning
Azimuth
Ending
Azimuth
Figure 42:  Azimuths Relative to Antenna’s Forward Arrow
ZONE 1= 335-025
 CHANGE       ACCEPT
Step 1:
Set Zone 1
Azimuth Range
ZONE 2= 000-000
 NEXT ITEM    CHANGE
Step 2:
Set Zone 2
Azimuth Range
XMT IN ZONES= NO
 NEXT ITEM    CHANGE
Step 3:
Set to “NO”
Figure 43:  Setup Process for RF Hazard Zones
Set Up RF Hazard Zones 
(Optional)