2.3 System Data Control
298
Feature Guide
2.
Remote Programming:
Conditions
Access to system programming is allowed only one at a time.
Programmer Code and Password for System Programming
To access system programming, a programmer code and its password must be entered. 
There are three programmer codes, which are set at the factory. Each programmer code 
has a unique password which is also set at the factory.
Programmer codes can be changed using the Maintenance Console, by selecting 
"Programmer Code Change" from the "Tool" menu. Passwords can be changed through 
system programming. If the wrong password is entered a preprogrammed number of times 
(Default: None [no limitation]) remotely, access will be locked and can only be unlocked by 
enabling remote access through system programming (
Method
Description
Using a modem 
(RMT card)
An RMT card must be installed. The floating extension number of 
the analogue remote maintenance must be assigned (
Floating Extension Number [811]).
PC programming, using a telephone connected in parallel with the 
modem, can be done in the following ways:
Direct Access
Dial the DIL/DID/DDI number whose destination is the floating 
extension number of the analogue remote maintenance.
Through DISA
Dial the floating extension number of the analogue remote 
maintenance using the DISA feature. (
Call Transfer
Call an extension (probably the operator), and request a 
transfer to the floating extension number of the analogue 
remote maintenance. (
Using an 
external modem 
(Not RMT card)
An external modem can be used instead of an RMT card to perform 
the remote programming. An external modem can be connected to 
the Serial Interface (RS-232C) of the PBX. Connect the modem to 
an extension port which is assigned as the DIL/DID/DDI/MSN 
destination or to a trunk directly to connect to the PBX from the PC. 
An AT command can be sent to the modem automatically when it 
is connected to the Serial Interface (RS-232C) port. AT commands 
can be programmed beforehand through system programming to 
initialise the modem. An AT command can also be sent manually in 
the PT system programming mode (
Using an ISDN 
TA interface (64 
kbps) through 
an ISDN Trunk
The floating extension number of the ISDN remote maintenance 
must be assigned (
[812]), and dial the DIL/DID/DDI/MSN number whose destination is 
the floating extension number of the ISDN remote maintenance. 
The RMT card is not required for this method.
This method is available only when an user-supplied ISDN TA that 
supports CAPI is used.