 0007VRF 
  Out_wait – Enter the time in milliseconds that the FXO port keeps waiting after 
seizing a telephony port and before dialing out DTMF signals. The default value is 
1000 millisecond. 
  Bat_vol – Before seizing a FXO port for dialing out, the FXO port detects voltage 
level on the port to ensure that the port is connected and available. If the voltage 
level is below this threshold level, the port is declared unavailable 
 
Call Progress 
 
This screen is for configuring the CP (Call Progress) tone detection for FXO port. For 
normal application, it is not recommended to modify the default settings. 
  Tone Detection – This specifies the ON/OFF of CP tone (busy tone for general 
case) cadence periods. For instance, On of Tone 1 is 500 and Off of Tone 1 is 500 
means the cadence is ON for 500ms then OFF for 500ms. If more than one ON/OFF 
cadence detections are required, for example, ON 300ms/OFF 400ms, then ON 
500ms/OFF 600ms, then program On of Tone 1 to be 300, Off of Tone 1 to be 400, 
On of Tone 2 to be 500, Off of Tone 2 to be 600. 
  Repeat Count – Input the minimum detection cycles for the above CP tone cadence. 
  Tone On Fraction – Input the CP tone sensitivity level. This parameter controls the 
SNR and frequency offset. The default value is 50%.