Configuring a terminal and SDI ports
553-3041-210 Standard 4.00 September 2007
•
Parity - none
•
Flow control - none
MG 1000E SDI connection
SDI connection to the MG 1000E is made at the back. See Figure 88 on
for location of the 9-pin DTE (male) connector. It is modified to
isolate pins 6, 7, and 8. Use PORT0 of NTBK48AA 3-port SDI cable for
terminal connection.
terminal connection.
Note: Connection must be made initially to each MG 1000E to set the
IP address.
IP address.
MG 1000T SDI connection
A terminal, modem, or other device (such as CDR devices and additional
TTYs) can be connected to the SDI ports. Follow Procedure 69 on
TTYs) can be connected to the SDI ports. Follow Procedure 69 on
to connect devices to Media Gateways.
Refer to Table 18 for SDI port numbering for MG 1000T Core and
MG 1000T Expansions.
MG 1000T Expansions.
Table 18
SDI port numbering for Media Gateways
SDI port numbering for Media Gateways
Media Gateway
Normal mode
Survival mode
MG 1000T Core
0, 1, 2
N/A
MG 1000T Expansion 1
3, 4, 5
0, 1, 2
MG 1000T Expansion 2
6, 7, 8
0, 1, 2
MG 1000T Expansion 3
9, 10, 11
0, 1, 2
MG 1000T Expansion 4
12, 13, 14
0, 1, 2