The wiring diagram below shows a typical wiring scheme for the telephone entry system. 
• 
Terminal 3 is a case ground and not a low voltage common.  Using terminal 3 as a low 
voltage common will cause noise on the phone line. 
• 
Switch input 1 (terminals 4 and 8) is pre-wired to the postal switch and pre-programmed to 
activate relay 1 when the input is closed. 
• 
Switch input 2 can be programmed to activate relay 2 or dial a preprogrammed phone 
number when the input is closed. 
 
2.2  WIRING  DESCRIPTION 
1
1 4
1 3
1 2
1 1
1 0
9
8
7
6
5
4
3
2
N o r m a l l y   O p e n
Switch 2 Input
Central Office
P h o n e   L i n e
E a r t h   G r o u n d
O n l y
N o r m a l l y   O p e n
Switch 1 Input
12 Volt
Battery
1 6   V A C ,   2 0   V A
T r a n s f o r m e r
+