Installing and wiring telephone power supplies
126 Installing and Connecting the MDF and Telephones
 
Figure 57: Connecting telephones and other end devices to the 1152B PDU 
For Data-In ports connect the Ethernet cable leading from the Ethernet Switch/Hub to the Data 
port. For Data & Power Out ports connect the Ethernet cable leading to the telephone or other 
end device to the corresponding Data & Power port.
Note:
Note:
Be certain to connect correspondingly numbered Data and Data & Power ports.
Connecting cables to telephones and other end devices 
An 1152B PDU contains line-sensing capabilities that enables it to send power only to end 
devices designed to receive power from the LAN. These end devices, termed Power over LAN 
Enabled, receive power once they are connected to the 1152B PDU. 
To safeguard devices that are not enabled, the 1152B PDU detects devices that are not enabled 
so does not send power. Note that data continues to flow using the Ethernet cable regardless of 
the status of the end device.
End devices that are not enabled to receive power directly may receive power and data through 
an external splitter. The external splitter separates the power and data prior to connection to the 
end device (see 
End Device
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
RJ-45 IN
RJ-45 OUT
Ethernet
Switch/Hub
RJ
-4
5
RJ
-4
5
data
data
data
DC +
data
DC -
data
data
data
data
spare
spare
spare
spare
Da
ta
 In
Da
ta
 &
 P
ow
e
r O
u
t
DC +
DC -
1152A1 Power Distribution Unit