Chapter 3: Installation 
34 of 60 
 
Extruder Setup 
Use this page to setup the Maximum Extruder RPM.  This is critical for GH Monitor 
units and GHF feeder units.  This value is automatically calculated with GH Full Control 
units.   
Also for GHF Feeder units you will need to program in the maximum LBS/HR of the 
extruder for the feeder’s target LBS/HR calculation. 
 
Figure 17: Extruder RPM Setup 
 
 
 
Hauloff Setup and Encoder Calibration Page (GH Full Control ONLY) 
Use this page to enable the hauloff option of the GH Full Control Unit.  The unit should 
be set to “Do not read speed from COEX Master” if a COEX AB does not exist.  If it 
does then this setting is automatically setup by the COEX Master.  The Hauloff max 
speed must be entered if you are not using an encoder (see mechanical options to turn this 
feature on/off).  If you are using an encoder then you must calibrate the encoder by 
running the line at a known speed, hand measuring the line speed with a tachometer, 
entering the speed into the ft/min box, and then clicking the “click here” box.  You can 
also manually modify this calibration by adjusting the “Distance per revolution of 
encoder”. 
Figure 17: Hauloff Setup and Encoder Calibration Page