Avaya S8100 Benutzerhandbuch
![Avaya](https://files.manualsbrain.com/attachments/539de53b12b0cfce0bb8cf1e3bb961e969d9f556/common/fit/150/50/0bfb423b07b431ecf5ac095ccde7771f5eac50e962dfba59f8e256280b3d/brand_logo.png)
1 Install and cable a G600 cabinet
Connect external alarms and auxiliary connections
114
S8100 Installation and Upgrades
November 2003
UPS alarm connection
Figure 33: UPS connection to G600 or CMC1
Table 15: Alarm output at AUX connector
Alarm output type
Color
AUX connector
EXTALMA
Violet-Green
(Pin 48)
EXTALMB
Green-Violet
(Pin 23)
Figure notes
1
Avaya UPS
2
Z3A2 alarm adapter
3
RJ45 (D8W) cable
4
103A or modular jack
5
Pin 26, white-orange
6
Pin 1, orange-white
7
Cross-connect field
8
25-pair cable
9
Processor Interface cable (AUX connector)
10
G600 or CMC1
OFF
cydmone2 LJK 042999
8
9
10
5
6
7
2
3
4
1