Installation 
TD4001FAUS Issue 1
 
Where to put your dryer 
 
•  Place your dryer at a distance from gas ranges, 
stoves, heaters, or cook tops because flames can 
damage the appliance. 
•  If you are going to install the appliance under a work 
counter, be sure to 
leave a 10 mm space 
between the top and 
any other objects on 
or above the 
machine and a 15 
mm space between 
the sides and lateral 
furnishings or walls. 
This is to ensure 
proper air circulation. 
Make sure that the 
back vents are not 
obstructed 
 
 
•  Make sure you put your dryer in an environment that is 
not damp and has proper air circulation throughout. 
The dryer will not operate efficiently in an enclosed 
space or cupboard. 
 
We do not recommend that the dryer be installed in a 
cupboard because dangerous levels of heat can build  
! The appliance must not be installed behind a lockable 
door, a sliding door or a door with a hinge on the opposite 
side to that of the tumble dryer in such a way that a full 
opening of the tumble dryer door is restricted
 
Ventilation 
 
This Dryer dries your laundry by drawing in cool, clean and 
relatively dry air, heating it, and then distributing it 
through the clothes as they are gently tumbled. For 
optimum performance, the moist air is then blown out 
through a vent tube behind the dryer. When the dryer is 
in use, there has to be adequate ventilation to avoid a 
back flow of gases into the room from appliances burning 
other fuels, including open fires. 
 
Mobile venting 
 
A vent tube must always be fitted when the dryer is used 
in conjunction with Mobile venting. The tube must be 
fitted securely into the back of the dryer (see Dryer 
Description). 
If possible, it is always best to connect the 
tube to a permanent vent close to the dryer. If permanent 
installation is not possible, the dryer will work just as well 
with the tube passing through a partly-opened window. 
Ensure that the end of the tube is not directed toward 
the air intake vent at the rear of the dryer. 
 
! The vent tube should not exceed 2,4 m in length, and 
should be kept free of any possible accumulation of 
fluff, lint, and water by shaking it out frequently. Always 
ensure that the tube is not squashed. 
 
Permanent venting 
In conjunction with the vent tube we recommend 
using a Wall/Window Vent Kit, available at a retail 
location or the nearest Spare Parts Dealer: 
 
Wall mounting 
1. Leave an opening in 
the wall to the left of 
dryer’s intended position. 
2. Keep the tube as 
short and straight as 
possible to prevent 
condensed moisture 
from backing up into 
the dryer. 
3. Similarly, the duct in the 
wall should slope 
downwards towards the 
outside. 
 
Window mounting 
1.  With a stacked dryer 
the hole in the 
window should ideally 
be made below the 
vent.  
2.  The tube should be 
kept as short as 
possible. 
 
Depending upon how often you use your dryer, it is 
essential that areas A and B are checked periodically 
to remove lint or debris. The vent tube adaptor must 
be fitted securely thus preventing any humid air from 
being emitted back into the room. 
 
! The Dryer should not be pushed so far back that the 
tube adaptor is pulled out of position or the tube is 
squashed or bent. 
 
! The tube should be kept clear of the air intake vent 
and kinks or ‘U’ bends must be avoided as these will 
obstruct the tube and trap condensation. 
 