Set Media Type
This parameter tells the printer the type of media that you are using (see 
 for more information). Selecting continuous 
media requires that you include a label length instruction in your label 
format (
^LLxxxx
 if you are using ZPL or ZPL II).
When non-continuous media is selected, the printer feeds media to 
calculate label length (the distance between two recognized registration 
points of the inter-label gap, webbing, or alignment notch or hole).
Default Value: NON-CONTINUOUS
Selections: NON-CONTINUOUS, CONTINUOUS
To change the value shown:
1.
Press 
PLUS (+)
 or 
MINUS (-)
 to scroll through the options.
Set Sensor Type
This parameter tells the printer whether you are using media with a web 
(gap/space between labels, notch, or hole) to indicate the separations 
between labels or if you are using media with a black mark printed on the 
back. If your media does not have black marks for registration on the back, 
leave your printer at the default (WEB).
Default Value: WEB
Selections: WEB, MARK
To change the value shown:
1.
Press 
PLUS (+)
 or 
MINUS (-)
 to toggle between the options.
Select Print Method
The print method parameter tells the printer the method of printing that you 
want to use: direct thermal (no ribbon) or thermal transfer (using thermal 
transfer media and ribbon). 
Default Value: THERMAL-TRANS.
Selections: THERMAL-TRANS., DIRECT THERMAL
To change the value shown:
1.
Press 
PLUS (+)
 or 
MINUS (-)
 to scroll through the options.