Cisco Systems ATA187I1ARF Benutzerhandbuch

Seite von 80
 
A-3
Cisco ATA 187 Analog Telephone Adaptor Administration Guide for SIP (Version 1.0)
OL-21862-01
Appendix A      ATA 187 Specifications
Ringing Characteristics
Ringing Characteristics
Software Specifications
Table A-5
Ringing Characteristics
Description
Specification
Tip/ring interfaces for each RJ-11 FXS port (SLIC)
Ring voltage
40V
RMS
 (typical, balanced ringing only)
Ring frequency
20 Hz
Ring waveform
Trapezoidal with 1.2 to 1.6 crest factor
Ring load
1400 ohm + 40
F
Ringer equivalence number (REN)
Up to 5 REN per RJ-11 FXS port
Loop impedance
Up to 200 ohms (plus 430-ohm maximum phone DC 
resistance)
On-hook/off-hook characteristics
On-hook voltage (tip/ring)
–48V
Off-hook current
24 mA (nominal)
RJ-11 FXS port terminating impedance option
The ATA 187-I1 provides multiple impedance, such 
as 600 ohm for American SKU, 900 ohm for 
European SKU, 220 ohm (820 ohm || 120nF) for 
Australian SKU, and so on. 
Table A-6
Software Specifications (All Protocols) 
Description
Specification
Call progress tones
Configurable for two sets of frequencies and single set of on/off 
cadence
Dual-tone multifrequency (DTMF)
DTMF tone detection and generation
Fax
Fax pass-through and T.38 fax relay mode.
Enhanced fax pass-through is supported on the Cisco ATA. 
Success of fax transmissions up to 14.4 kbps depends on 
network conditions, and fax modem/fax machine tolerance to 
those conditions. The network must have reasonably low 
network jitter, network delay, and packet-loss rate.