Paradyne and 8985 Benutzerhandbuch
3. Configuration Using the Web Interface
3-7
3. Click on Apply.
Creating Line Profiles for Ports (8985)
Procedure
To create a line profile for SHDSL ports:
1. Click on Create New Profile. The SHDSL Profile Create screen appears.
2. Enter or select the following fields:
3. Click on Apply.
Field
Description
Profile Name
Specify a name for this line profile.
Max Rate
Enter a maximum rate from 192 to 2304 kbps.
Min Rate
Enter a minimum rate from 192 to 2304 kbps.
Mode
Select the regional setting supported, as specified by
ITU-T G.991.2:
ITU-T G.991.2:
Annex A
Annex B
Both
Remote Management
Select Enable or Disable from the drop-down list to
determine whether remote management is supported for
the network element this profile is assigned to.
determine whether remote management is supported for
the network element this profile is assigned to.
Reference Clock
Select the timing source from the drop-down list:
System – Clocking is provided by the backplane. (The
backplane clock is configured on the Configuration -
System - Clocking screen.)
backplane clock is configured on the Configuration -
System - Clocking screen.)
Local – Clocking is provided by an onboard oscillator.
Target Margin
Enter a target noise margin from 2–15 dBm, or None.
Interface
Select an interface from the drop-down list:
Wire Pair 1 – The profile applies to Wire Pair 1.
Wire Pair 2 – The profile applies to Wire Pair 2.
Select Wire Pair 1 if this profile is to be used for ports that
use only one wire pair.
use only one wire pair.