Paradyne 8968 Benutzerhandbuch

Seite von 50
3. Configuration Using the Web Interface
3-7
3. Click on Apply.
Creating Line Profiles for Ports (8985)
Procedure
To create a line profile for SHDSL ports:
1. Click on Create New Profile. The SHDSL Profile Create screen appears.
2. Enter or select the following fields:
3. Click on Apply.
Field
Description
Profile Name
Specify a name for this line profile.
Max Rate
Enter a maximum rate from 192 to 2304 kbps.
Min Rate
Enter a minimum rate from 192 to 2304 kbps.
Mode
Select  the regional setting supported, as specified by 
ITU-T G.991.2: 
„
Annex A
„
Annex B
„
Both
Remote Management
Select Enable or Disable from the drop-down list to 
determine whether remote management is supported for 
the network element this profile is assigned to.
Reference Clock
Select the timing source from the drop-down list:
„
System – Clocking is provided by the backplane. (The 
backplane clock is configured on the Configuration - 
System - Clocking screen.)
„
Local – Clocking is provided by an onboard oscillator.
Target Margin
Enter a target noise margin from 2–15 dBm, or None.
Interface
Select an interface from the drop-down list:
„
Wire Pair 1 – The profile applies to Wire Pair 1.
„
Wire Pair 2 – The profile applies to Wire Pair 2.
Select Wire Pair 1 if this profile is to be used for ports that 
use only one wire pair.