Paradyne 8968 Benutzerhandbuch

Seite von 50
3. Configuration Using the Web Interface
3-10
 
Creating Alarm Threshold Profiles for Model 8985
Procedure
To create an alarm threshold profile for an SHDSL line card:
1. Click on Create New Profile. The Alarm Threshold Profile Create screen 
appears.
2. Enter or select the following fields:  
Field
Description
Profile Name
Specify a name for this alarm profile.
Loop Attenuation Threshold
Specify a loop attenuation alarm threshold of 0–127 dB. 
An SNMP Loop Attenuation crossing trap message and a 
TL1 autonomous message may be sent if the current loop 
attenuation reaches or exceeds this threshold. A Loop 
Attenuation alarm will also be declared when the current 
Loop Attenuation exceeds this value. A value of 0 disables 
event notifications for the condition. 
SNR Margin
Specify an SNR Margin alarm threshold of 0–15 dB. An 
SNMP Margin crossing trap message and a TL1 
autonomous message may be sent if the current SNR 
Margin reaches or drops below this threshold. An SNR 
Margin alarm will also be declared when the current SNR 
Margin has dropped below this value. A value of 0 
disables event notifications for the condition.
Errored Seconds
Specify an ES threshold of 0–900 seconds. An SNMP ES 
trap message and a TL1 autonomous message may be 
sent if the number of ES events in a 15-minute interval 
equals or exceeds the selected value. At most one SNMP 
and one TL1 notification will be sent per interval per 
device. A value of 0 disables event notifications for the 
condition.
Severely-Errored Seconds
Specify an SES threshold of 0–900 seconds. An SNMP 
SES trap message and a TL1 autonomous message may 
be sent if the number of SES events in a 15-minute 
interval equals or exceeds the selected value. At most one 
SNMP and one TL1 notification will be sent per interval 
per device. A value of 0 disables event notifications for the 
condition.
Code Violations
Specify a Code Violations threshold of 0–900 seconds. An 
SNMP code violations trap message and a TL1 
autonomous message may be sent if the number of Code 
Violations in a 15-minute interval equals or exceeds this 
threshold. At most one SNMP and one TL1 notification will 
be sent per interval per device. A value of 0 disables event 
notifications for the condition.