Olympus AX70 Benutzerhandbuch
![Olympus](https://files.manualsbrain.com/attachments/b7a34880446dea790ffdaa480e65b5744f9552e9/common/fit/150/50/6c6d826860f4f5b4765268022bc57c234dfeb35a0883c09335a0df1e3980/brand_logo.jpeg)
Item
Type
Y-shape frame with built-in transmitted/incident light vertical illuminator
Optical system
UIS optical system (infinity-corrected/compensation-free)
Transmitted illumination
12V100W halogen (2,000 hours long-life type), pre centered
Mechanical field diaphragm (motorized field diaphragm unit attachable)
Six built-in manual filters (ND1.5, ND3, ND6, ND12, IF550, LBD; motorized filter changer attachable)
One optional external filter can be user-installed (manual operation)
Mechanical field diaphragm (motorized field diaphragm unit attachable)
Six built-in manual filters (ND1.5, ND3, ND6, ND12, IF550, LBD; motorized filter changer attachable)
One optional external filter can be user-installed (manual operation)
Incident illumination
Universal vertical illuminator, 12V100W halogen/Hg100W/Xe75W applicable, optical devices detachable, motorized mirror unit changer, excitation light
shutter (interlocking operation when changing an objective/observation method). Max. three filter sliders (six filters) attachable (when using AX-RFCH)
shutter (interlocking operation when changing an objective/observation method). Max. three filter sliders (six filters) attachable (when using AX-RFCH)
Illumination adjustment
1-12V (adjustable in units of 0.1V by the jog dial), light preset switch, transmitted/incident halogen illumination changeover switch
Focus
Vertical stage movement by manual roller guide, stage travel range: 25mm. Coaxial coarse and fine focus handle, minimum fine focus adjustment
graduation: 1
graduation: 1
µ
m increments, stroke per rotation: 0.1mm (fine), 15mm (coarse). Sensitivity: less than 1
µ
m
Operation control position
Main switch located at power supply (U-PS), light adjustment dial: right front, field control knob: left front, sub-main switch, changeover switch for
transmitted/incident illumination, light preset switch: right wing of frame, hand switch attached (objectives direct changeover, objectives recall, mirror unit
direct changeover. Incident excitation shutter on/off, lamp off possible)
transmitted/incident illumination, light preset switch: right wing of frame, hand switch attached (objectives direct changeover, objectives recall, mirror unit
direct changeover. Incident excitation shutter on/off, lamp off possible)
Power supply (U-PS)
100/120/220/230/240 V automatic changeover, main switch attached
Observation tube
(when using U-SWTR-2)
F.N. 26.5 (super widefield), adjustable
interpupillary distance range: 50-76mm,
inclined 24
F.N. 26.5 (super widefield), adjustable
interpupillary distance range: 50-76mm,
inclined 24
゜
, right eyepiece sleeve correction
mechanism, photo focusing can be attached,
reticle/photo mask rotation stop included,
(erect image, U-SWETR attachable)
reticle/photo mask rotation stop included,
(erect image, U-SWETR attachable)
Revolving nosepiece
Motorized sextuple nosepiece, motorized quintuple nosepiece for reflected darkfield observation, various manual nosepieces attachable
Stage
Stroke range: 52
×76mm (with vernier), max two sliders can be inserted, torque adjustable, selectable from right handle or left handle, knob position (tip):
57mm from desk top
Condenser holder
Vertical stroke range: 25mm (when using AX-UCDM: 10mm), centering adjustment function (AX-UCDM: standard feature), both sides condenser
movement control knobs, (AX-UCDM: motorized)
movement control knobs, (AX-UCDM: motorized)
Observation tube
F.N. 26.5 (super widefield), adjustable interpupillary distance range: 50-76mm, inclined 24
゜
,
magnification [(direct optical path: 1
×, optical path through zoom: 1-2× (zoom)]
Camera
Two 35mm cameras, one large-format camera, one video camera (all can be attached at the same
time); two video cameras can be mounted by connecting U-TVL to the large-format port; selectable by
U-MCB
time); two video cameras can be mounted by connecting U-TVL to the large-format port; selectable by
U-MCB
•
U-PHOTO/U-AFPHOTO
[Direct optical path]
BI : video camera (direct) = 100:0/0:100
[Peripheral optical path] (all light goes to camera optical path during exposure)
BI : video camera (direct) : video camera 2 : photometry
= 100:0:0:0 / 0:100:0:0 / 0:0:100:0 / 20:0:0:80 / 0:20:0:80
= 100:0:0:0 / 0:100:0:0 / 0:0:100:0 / 20:0:0:80 / 0:20:0:80
(video camera 2 is mounted to the large-format port via U-TVL.)
※ When using auto focus function of U-AFPHOTO:
BI : video camera (direct) : video camera 2 : photometry : AF sensor
= 50:0:0:0:50 / 0:50:0:0:50 / 0:0:50:0:50 / 10:0:0:80:10 / 0:10:0:80:10
BI : video camera (direct) : video camera 2 : photometry : AF sensor
= 50:0:0:0:50 / 0:50:0:0:50 / 0:0:50:0:50 / 10:0:0:80:10 / 0:10:0:80:10
[Camera optical path]
35mm left : large-format : 35mm right = 100:0:0 / 0:100:0 / 0:0:10:0
※ When using video camera 2
35mm left : 35mm right = 100:0 / 0:100
※ When using video camera 2
35mm left : 35mm right = 100:0 / 0:100
•
U-PHOTO20/80
[Direct optical path]
BI : video camera (direct) = 100:0 / 0:100
[Peripheral optical path] (80% of all light goes to camera optical path during exposure)
BI : video camera (direct): video camera 2 : photometry
= 20:0:80:0 / 100:0:0:0 / 0:100:0:0 / 20:0:0:80 / 0:20:0:80
= 20:0:80:0 / 100:0:0:0 / 0:100:0:0 / 20:0:0:80 / 0:20:0:80
(video camera 2 is mounted to large-format port via U-TVL)
[Camera optical path]
35mm left : large-format : 35mm right = 100:0:0 / 0:100:0 / 0:0:100
※ When using video camera 2
35mm left : 35mm right = 100:0 / 0:100
※ When using video camera 2
35mm left : 35mm right = 100:0 / 0:100
Photo magnification
35mm camera: 2.5x-5x, large-format camera: 7.5x-15x
Zoom
Motorized control by jog dial or fixed magnification switch of U-MCB. Zoom ratio: 2
×
Focusing telescope
Manual insertion, magnification ratio: 3.4
× (besides U-AFPHOTO)
Photo frame reticle
Manual insertion, bright frame operation (red/yellow), illumination adjustment (seven levels)
Shutter
Pulse-control electromagnetic shutter, shutter speed: max. 1/125 sec.
Photometry
2D image analysis memory mode by the CCD. 0.1% spot measurement, 1% spot measurement, 30%
average measurement switchable. Flexible spot measurement area, spot color switchable (red/yellow)
average measurement switchable. Flexible spot measurement area, spot color switchable (red/yellow)
Photometry conditions
Five exposure modes: Auto mode, FL Auto mode, Super FL Auto mode, Manual mode, time mode.
Auto exposure range: 1/125 sec.-68min. ISO: 3-25,600 (automatic setting by DX method, manual
setting also possible). 13-step exposure control (0.25-4, every 1/3 step). Auto bracketing function,
eight-level reciprocity failure correction, multi-exposure, AE lock, exposure time recall,, data/scale
imprinting function (by imprinting unit)
Auto exposure range: 1/125 sec.-68min. ISO: 3-25,600 (automatic setting by DX method, manual
setting also possible). 13-step exposure control (0.25-4, every 1/3 step). Auto bracketing function,
eight-level reciprocity failure correction, multi-exposure, AE lock, exposure time recall,, data/scale
imprinting function (by imprinting unit)
Camera back
35mm (PM-C35DX): auto loading/wind/rewind and automatic film detection, data imprinting unit can be
attached, automatic setting of the ISO value by the DX code. Frame counting number is retained for
data back-up. Data imprinting unit (PM-DI-35): backlit exchange type
Large-format camera back (attached to U-DLF); Polaroid (PM-CP-3)
attached, automatic setting of the ISO value by the DX code. Frame counting number is retained for
data back-up. Data imprinting unit (PM-DI-35): backlit exchange type
Large-format camera back (attached to U-DLF); Polaroid (PM-CP-3)
Operation by transmitted touch panel and jog dial sheet switch. Graphics indicated on plasma display.
Centralized control of mentioned photomicrography conditions and all motorized parts are possible.
Memory card function: can register, recall, delete, print the information of photometry and observation.
External interface function: selectable from RS232C, GPIB or printer interface (optional)
Centralized control of mentioned photomicrography conditions and all motorized parts are possible.
Memory card function: can register, recall, delete, print the information of photometry and observation.
External interface function: selectable from RS232C, GPIB or printer interface (optional)
Optical path difference based contrast system. Operation modes: real-time mode and one-shot mode
(switchable). Applicable magnifications: 1.25
(switchable). Applicable magnifications: 1.25
×-100×. Applicable condensers: AX-UCDM, U-UCDB,
U-AAC, U-ULC-2. Applicable microscopic observation: brightfield/darkfield, Nomarski DIC, polarized
light (both transmitted and incident light), fluorescence (incident light only)
light (both transmitted and incident light), fluorescence (incident light only)
Eyepiece
10x, F.N. 26.5 (super widefield of view)
Condensers
Universal motorized condenser for AX (AX-UCDM): N.A. 0.16-0.9 (N.A. 0.16-1.4 with change of top lenses), objectives (1.25
×-100×). Turret, aperture
diaphragm, top lens changeover polarizing plate attachment insertion: all motorized. Applicable for transmitted brightfield, transmitted darkfield, transmitted
phase-contrast, transmitted Nomarski DIC, transmitted simple polarizing observations.
Swing-out Achromat (U-SC): N.A. 0.16-0.9, objectives (2
phase-contrast, transmitted Nomarski DIC, transmitted simple polarizing observations.
Swing-out Achromat (U-SC): N.A. 0.16-0.9, objectives (2
×-100×). Achromat/Aplanat (U-AAC): N.A. 1.4, objectives (10×-100×). Universal (U-UCDB):
N.A. 0.2-0.9 , objectives (2
×-100×). Phase-contrast darkfield (U-PCD): N.A. 1.25, objectives (10×-100×). For super low magnification (U-ULC-2): N.A.
0.16, objectives (1.25
×-4×). Darkfield (dry): N.A. 0.8-0.92, objectives (10×-40×). Darkfield (oil): N.A. 1.20-1.40, objectives (10×-100×)
22
Photomicrography unit
AX70 specifications
Microscope stand
Integrated in photomicrographic unit
AX70+U-PHOTO/U-PHOTO20/80/U-AFPHOTO
AX70
PLAPO set: PLAPO2
×
UPLAPO4
×
UPLAPO10
×
UPLAPO20
×
PLAPO40
×
PLAPO100
×O
UPLAPO set: PLAPO2
×
UPLAPO4
×
UPLAPO10
×
UPLAPO20
×
UPLAPO40
×
UPLAPO100
×O
UPLAFL set: PLAPO2
×
UPLAFL4
×
UPLAFL10
×
UPLAFL20
×
UPLAFL40
×
UPLAFL100
×O
(*1) Conform to ISO9345-1, ISO8038.
Auto focus
(on U-AFPHOTO only)
(on U-AFPHOTO only)
Objectives
—
—
—
—
—
—
—
—
—
—
—
—
—
Optical path changeover
Conform to ISO (*1)
Multi-control box
(U-MCB)
(U-MCB)