Intel 8XC196MD Benutzerhandbuch
8XC196MC, MD, MH USER’S MANUAL
9-8
The main differences between the center-aligned modes and among the edge-aligned modes are
the events that control register updates. Table 9-4 lists the events that can cause register updates
and the registers that are updated in each mode.
the events that control register updates. Table 9-4 lists the events that can cause register updates
and the registers that are updated in each mode.
Table 9-3. Operation in Center-aligned and Edge-aligned Modes
Step
Center-aligned Modes
Edge-aligned Modes
1
Load WG_COUNTER with WG_RELOAD.
Leave outputs deasserted.
Leave outputs deasserted.
Load WG_COUNTER with 0001H.
Leave outputs deasserted.
Leave outputs deasserted.
2
When counter is enabled, begin counting down.
When WG_COUNTER reaches 1, wait 1 state,
then begin counting up. Assert outputs when up
count begins.
then begin counting up. Assert outputs when up
count begins.
When counter is enabled, begin counting up.
Assert outputs when up count begins.
Assert outputs when up count begins.
3
When WG_COUNTER reaches the
WG_COMP
WG_COMP
x
value during the up count, deassert
the corresponding phase’s outputs and continue
counting up.
counting up.
When WG_COUNTER reaches the
WG_COMP
WG_COMP
x
value, deassert the corresponding
phase’s outputs and continue counting up.
4
When WG_COUNTER reaches the
WG_RELOAD value, begin counting down.
WG_RELOAD value, begin counting down.
When WG_COUNTER reaches the
WG_RELOAD value, update WG_RELOAD and
go to step 1.
WG_RELOAD value, update WG_RELOAD and
go to step 1.
5
When WG_COUNTER reaches the
WG_COMP
WG_COMP
x
value during the down count,
assert the corresponding phase’s outputs and
continue counting down.
continue counting down.
6
When WG_COUNTER reaches 1, deassert
outputs, update WG_RELOAD, and go to step 1.
outputs, update WG_RELOAD, and go to step 1.
Table 9-4. Register Updates
Event
Center-aligned Modes
Edge-aligned Modes
Mode 0
Mode 1
Mode 2
Mode 3
Mode 4
(MH Only)
Registers Updated
Registers Updated
WG_COUNTER
= WG_RELOAD
= WG_RELOAD
WG_RELOAD
WG_COUNTER
WG_COMP
x
WG_OUTPUT
†
WG_RELOAD
WG_COUNTER
WG_COMP
x
WG_OUTPUT
†
WG_RELOAD
WG_COUNTER
WG_COMP
x
WG_OUTPUT
†
WG_RELOAD
WG_COUNTER
WG_COMP
x
WG_OUTPUT
†
WG_RELOAD
WG_COUNTER
WG_COMP
x
WG_OUTPUT
†
WG_COUNTER = 1
—
WG_COMP
x
—
—
—
EPA event
WG_OUTPUT
†
WG_OUTPUT
†
WG_OUTPUT
†
WG_RELOAD
WG_COUNTER
WG_COMP
x
WG_OUTPUT
†
WG_OUTPUT
†
†
The WG_OUTPUT register is updated under these conditions if its synchronization bit is set;
otherwise, changes take effect immediately.