Fiber (FX) Port 
Multimode ST, SC, Single mode SC
 
100Mbps Full-duplex and half-duplex support
 
MMF 50/125µm, 62.5/125µm fiber cable
 
SMF 9/125µm cable
 
Far End Fault Indication support
Flow Control 
IEEE 802.3x for full-duplex, Back pressure for half-duplex
LEDs 
- Power status
 
- TP port link, activity, speed, duplex status
 
- Per FX port link, activity, optical link status
Configuration Setting Switches 
Auto/forced mode, TP speed, TP duplex FXduplex
DC Power Input     
Screwed terminator block :  2 pairs of +/- contacts
         
DC jack :  
  -D 6.3mm / + D 2.0mm
 
Operating voltage range :  +7 - +30VDC
Power Consumption 
3W max. @30VDC power input
Dimension 
28  x 82 x 95 mm, Weight : 250g
Housing 
Enclosed metal with no fan
Mounting Support    
DIN Rail mounting, Panel mounting
Environment      
Operating Temperature:  See ordering information 
 
Storage Temperature:   -20
O
C ~ 85
O
C
 
Relative Humidity:  
5% ~ 95% non-condensing
Approval       
FCC Class B, CE/EMC Class B, EN60950 safety 
Fiber Optical Specification :
Model  
FX &Cable 
Wavelength   Tx Power  
Rx Sensitivity   Rx Max.Power
-T  
ST MMF 
1310nm  
-19 ~-14 dBm   -31 dBm 
-14 dBm
-C  
SC MMF  
1310nm  
-19 ~-14 dBm   -31 dBm 
-14 dBm
-C1  
SC MMF  
1310nm  
-20 ~-14 dBm   -31 dBm 
0 dBm
-SA2  
SC SMF  
1310nm  
-15 ~-8 dBm  
-31 dBm 
-7 dBm
-SL2  
SC SMF  
1310nm  
-15 ~-8 dBm  
-30 dBm 
-7 dBm
-SL3  
SC SMF  
1310nm  
-15 ~-8 dBm  
-34 dBm 
0 dBm
-SL4  
SC SMF  
1310nm  
-5 ~0 dBm  
-35 dBm 
-3 dBm
-SL10  
SC SMF  
1550nm  
-5 ~0 dBm  
-35 dBm  
-3 dBm
-W3515 
Bi-Di SC SMF 
Tx 1310nm 
-14 ~-8 dBm  
-31 dBm 
0 dBm
 
 
Rx 1550nm
-W5315 
Bi-Di SC SMF 
Tx 1550nm 
-14 ~-8 dBm  
-31 dBm 
0 dBm
 
 
Rx 1310nm
EMI EMS Safety Environmental Tests :
Ordering Information :
Specifications
Class B
Class B
< 75 W
Clause 5
+/-8KV
Power:+/-4KV
Data:+/-2KV
Level 3
50Hz 40A/m
Interruption : C
Dips : A
Strength:10V/m
TP, 1500VAC/60sec.
TP, 500VDC/10Mohm
-20
O
C, 96hrs
+70
O
C 40%RH 96hrs
+60
O
C 90%RH 96hrs
Test
FCC/EMI
CE/EMC/EMI
CE/EMC/Harmonic
CE/EMC/VFF
CE/EMC/EMS
ESD Test
RS Test
EFT/BURST
Surge Immunity
CS Test
Magnetic Field Imm.
Voltage Dips Imm.
Safety
Dielectric Voltage
Insulation Resistance
Cold Test
Dry Heat Test
Damp Heat Test
Storage Test
Vibration Test
Standard
FCC Rule Part 15
EN55022, CISPR 22
EN 61000-3-2
EN 61000-3-3
EN 55024
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
EN 60950, IEC 60950
IEEE 802.3
IEEE 802.3
IEC 68-2-1 Test Ad
IEC 68-2-2 Test Bd
IEC 68-2-3
IEC 68-2-48
IEC 68-2-34
+85
O
C 40%RH 96hrs
-20
O
C 96hrs
-T
-C 
Operating
Temperature
-10 ~ 70
O
C
-10 ~ 70
O
C
-20 ~ 70
O
C
-20 ~ 70
O
C
-20 ~ 70
O
C
-20 ~ 70
O
C
ST MMF
FX Port
Fiber
Model
KCD-300-xxx
SC MMF
SC MMF
-C1  
SC SMF
-SA2
SC SMF
-SL3
SC SMF
-SL4
2km
Ref.
Distance
2km
2km
20km
30km
-20 ~ 70
O
C
SC SMF
-SL2
20km
40~50km
-20 ~ 70
O
C
SC SMF
-SL10
100km
KCD-3PB 
Panel mounting
bracket for KCD-300
-20 ~ 70
O
C
Bi-Di SC SMF
-W3515
15~20km
-20 ~ 70
O
C
Bi-Di SC SMF
-W5315