B&B Electronics 1939STB Benutzerhandbuch

Seite von 40
14  1939STB4600 
Manual 
 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Commercial  Park – Oranmore, Galway, Ireland – Ph +353 91 792444 – Fax +353 91 792445 
 
 
Message Header Setup 
 
Before a message can be sent to the SAE-J1939 bus, the message header 
must be configured to direct the data correctly. The following table shows the 
bytes that must be set to direct a message to the SAE-J1939 bus. 
 
The first two bytes are for the start of message. The third byte (B3) 
containing hex 1F,1 directs the message to the J1939 bus. (F) hex is the 
number of bytes in the payload. Byte four (B4) tells the converter in which 
message slot to put the message (slot 5). Valid slots are 1 through 15, but slot 
15 is reserved for receive only. 
 
 
Table 21.  Valid Codes for Byte 4
 
Function 
Nibble 2 
Nibble 1 
No function (reserved) 
Value = 0 
 
Message slot number 
 
Value = 1 to 15 (1 to F hex) 
 
 
 
 
 
Each message must have a unique slot number. A message sent 
to the same slot number overwrites the previous message. 
Table 19.  J1939 Message Header 
Message Header 




81 21 1F 
05 
 
 
 
 
Table 20. Valid Codes for Byte 3 
Nibble 2 
Value 
Function 
 
   1 
Message directed to SAE-J1939 bus 
 
   2 
Internal commands, vender #, baud change 
Nibble 1 
 
 
 
 0 to 15 
Number of bytes to follow byte 4