Function 
This is used to show where the message came from. Refer to Table 37. If  
the Nibble 2 is set to 0, then the message is from the J1939 bus. If Nibble 2 is 
set to 2, it is an internal message (for example, Vendor ID). 
 
 
 
 
 
 
MC 
This is a byte from the controller. Nibble 2 is the number of data bytes (0-
8) in the message. Nibble 1, Bit 3 is the message direction. Bit 2 should 
always be set to 1. Bit 1 and 0 are not used. 
Table 38.  MC 
                        Nibble 2 
                  Nibble 1 
 Bit  7 
Bit 6 
Bit 5 
Bit 4 
Bit 3 
Bit 2 
Bit 1 
Bit 0