Control Byte 3 
 
Byte 3 directs the data packet to the proper destination.  The setting of 
this byte will affect the rest of the message. That is to say changing this byte 
changes the meaning of the following data bytes. 
 
Byte 3 has two parts, Nibble 1 and Nibble 2.  Nibble 2 (bits 4 – 7) sets 
the control code as follows: 
Nibble 1 (bits 0 – 3) of control byte 3 defines the number of bytes in the 
data payload of the message. The byte count does NOT include the message 
header (bytes 1 through 4). The message payload is limited to 16 bytes. This 
limit allows a complete J1939 packet to be sent or received from the bus. 
 
 
Nibble 1 of control byte 3 can be set to any value between 0 and 16 
(0 to F hex).
Table 3.  Bits of Byte 3 
                     Nibble 2 
                  Nibble 1 
Bit 7 
Bit 6 
Bit 5 
 Bit 4 
 Bit 3 
 Bit 2 
Bit 1 
  Bit 0 
Table 4.  Byte 3 Nibble 2
Bit Number 
Value 
Function 
   1 
Reserved  not used 
Bit 7 
   0 
Reserved not used 
   1 
Reserved  not used 
Bit 6 
   0 
Reserved  not used 
   1 
Internal commands (Baud rate, Version number) 
Bit 5 
   0 
No function 
   1 
External commands (Messages to J1939 bus) 
Bit 4 
   0 
No function
Table 5.  Transmit Data Format
Byte 1 
Byte 2 
Byte 3 
Byte 4 
Message Information   
Data Payload 
Check 
Check 
Control 
Control 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
 
<< Count Number of Bytes for byte 3 nibble 1 >> 
Table 6.  Byte 3 Nibble 1 
Bit Number 
Value 
Function 
   1 
Number of bytes in data payload (MSB) 
Bit 3 
   0 
 
   1 
Number of bytes in data payload 
Bit 2 
   0 
 
   1 
Number of bytes in data payload 
Bit 1 
   0 
 
   1 
Number of bytes in data payload (LSB) 
Bit 0 
   0