DCS 954 Benutzerhandbuch

Seite von 89
dCS 954 User Manual
 Manual for Standard Software Version 1.5x
dCS Ltd 
June 2000
Manual part no: DOC136954 iss 2B1
Page 76
file 135954ma2b1.pdf available from website
Contact 
dCS
 on + 44 1799 531 999 
email to: more@dcsltd.co.uk
(inside the UK replace + 44 with 0)
web site: www.dcsltd.co.uk
T
ROUBLE
S
HOOTING
Error Codes and Messages
The error codes and messages reported by dCS 954 provide an effective means
to diagnose the majority of problems that may be encountered in use - including
problems with the overall system the unit operates in, internal device warnings
and internal device failures. Please note that through damage or component
failure, the unit self check may fail to operate. If this happens, please contact
your distributor or dCS for assistance.
Internal Device Error Codes
Sometimes the unit may misbehave. If there is an internal reason, an internal
device error code may be displayed as follows:
Err.xy
an error xy (see table below) has been detected
where 
xy
 values have the following meanings:
Code
Description
01
E
2
 memory (EEPROM) not present
02
Error initialising DSP
03
Error loading DSP
04
Error initialising DSP for coefficients
05
Error initialising DSP for coefficients
06
Error loading DSP coefficients
07
Error loading DSP coefficients
08
Error sending command
09
Error sending command
10
Error sending command
11
Error sending command
12
Error with LSB/MSB configuration
13
Error with LSB/MSB configuration
14
Error with LSB/MSB configuration
15
Error configuring FPGA
99
DSP error
Table 13 – Internal Error Codes
If you get any of these, please contact dCS, with as much information as
possible to help us re-create the problem. Some of these may have hardware
problems as their cause, some may have software.