Benutzerhandbuch (SFS-3504)InhaltsverzeichnisCisco SFS 3504 Multifabric Server Switch Hardware Installation Guide1Prefacevii3chapter 13CiscoSFS3504 Server Switch Overview1-13chapter 23Preparing to Install2-13chapter 34Installing the CiscoSFS3504 Server Switch3-14chapter 44Installing and Removing Field-Replaceable Units4-14chapter 55CiscoSFS3504 Server Switch LEDs5-15appendix A5Specifications and ComplianceA-15appendix B5Acronyms and AbbreviationsB-15Index5Preface7Audience7Organization7.7Conventions8Statement 1071—Warning Definition9Related Documentation15Obtaining Documentation and Submitting a Service Request15117CiscoSFS3504 Server Switch Overview17Introduction17System Features18IB Connectivity18Performance18Unified Fabric18Transparent Topology18Redundancy and High-Availability19Figure1-1 Redundancy with Two Cisco SFS 3504 Server Switches19Scalability19CiscoSFS3504 Server Switch Chassis20Figure1-2 CiscoSFS3504 Server Switch in a Typical Configuration - Data Connection End20Figure1-3 CiscoSFS3504 Server Switch Chassis in a Typical Configuration - Power-Fan Modules End21Figure1-4 Location of AC Power-Fan Module Slot Identification Numbers21Cards, Modules, and Panels for the CiscoSFS3504Chassis22InfiniBand Switch Card22Figure1-5 InfiniBand Switch Card22Fibre Channel Gateway Card23Figure1-6 4-Port Fibre Channel Gateway Card23Ethernet Gateway Card23Figure1-7 6-port Ethernet Gateway Card23AC Power-Fan Module24Figure1-8 AC Power-Fan Module24Blanking Panels for the CiscoSFS3504 Server Switch Chassis24Figure1-9 Blanking Panel for Gateway Module Slot25Figure1-10 Blanking Panel for AC Power-Fan Module Slot25LEDs25Rail Kit for Rack Mounting25Figure1-11 CiscoSFS3504 Server Switch with Premounted Guide Rails26227Preparing to Install27Safety27Site Requirements27Temperature28Humidity28Altitude29Dust and Particles29Corrosion29Electromagnetic and Radio Frequency Interference29Shock and Vibration30Power Source Interruptions30Preventing Electrostatic Discharge Damage31Air Flow31Figure2-1 Air Flow Direction in the CiscoSFS3504 Server Switch31Power Requirements32Site Preparation Checklist32Table2-1 Site Planning Checklist32335Installing the CiscoSFS3504 Server Switch35Safety35Preparing to Install37Step1 Remove all components from the CiscoSFS3504 Server Switch shipping container, and identi...37Step2 Place the chassis on a secure, clean surface.37Step3 Verify that you have the parts for the rail kit for rack mounting (shipped with the Cisco...37Step4 Verify that you have at hand all Ethernet gateways and Fibre Channel gateways that you nee...37Step5 Prepare a management workstation (not included), such as a PC running terminal-emulation s...37Installing CiscoSFS3504 Server Switch Components38Mounting the CiscoSFS3504 Server Switch on a Rack38Installing with the Power-Fan Modules Flush-front39Step1 Open the bag that contains the mounting hardware.39Step2 Attach the two rack ear brackets to the power-fan module end of the chassis using a Philli...39Figure3-1 Attaching the Rack-Mounting Ear Brackets at the Power-Fan Module End39Figure3-2 Sliding the Cisco SFS 3504 Server Switch Between Rack Posts and Inserting Brackets40Step3 Slide the CiscoSFS3504 Server Switch between the rack posts (see Figure3-2), until the ...40Step4 Slide the two adjustable brackets, from the back, between each of the guide rails that are...40Step5 Adjust the adjustable brackets so that the holes in the brackets align with the holes in t...41Installing with the Data-Connection Cables Flush-front41Step1 Open the bag that contains the mounting hardware.41Step2 Remove the two guide rails that are attached on either side of the CiscoSFS3504 Server S...42Figure3-3 Attaching the Guide Rails at the Power-Fan Module End42Step3 Attach the two rack ear brackets to the data-connection end of the chassis using a Phillip...43Figure3-4 Attaching the Rack-Mounting Ear Brackets to the Data Connection End43Step4 Slide the CiscoSFS3504 Server Switch between the rack posts (see Figure3-5), until the ...43Figure3-5 Sliding the Cisco SFS 3504 Server Switch Between Rack Posts and Inserting Brackets44Step5 Slide the two adjustable brackets, from the back, between each of the guide rails that are...44Step6 Adjust the adjustable brackets so that the holes in the brackets align with the holes in t...44Attaching a Serial Console Cable to a PC or Terminal45Step1 Connect the cable from the serial console port on the controller module to your terminal o...45Step2 Open a terminal emulation window using a program such as HyperTerminal for Windows. Set yo...45Connecting InfiniBand Hosts45Figure3-6 InfiniBand Cable with Pinch Connector45Figure3-7 InfiniBand Cable with Pull Connector46Figure3-8 Removing a Pinch Connector46Figure3-9 Removing a Pull Connector47Managing the CiscoSFS3504 Server Switch47449Installing and Removing Field-Replaceable Units49InfiniBand Switch Card49Installing an InfiniBand Switch Card50Step1 Ground yourself using an approved ground wrist strap.50Step2 Remove the switch card from any packaging.50Step3 Extend the ejector levers on either side of the switch card completely.50Step4 Insert the switch card all the way into slot 5.50Step5 Press the switch card firmly into the slot.50Figure4-1 Installing a Switch Card50Step6 Close both ejector levers simultaneously and completely.51Figure4-2 Securing the InfiniBand Switch Card51Removing an InfiniBand Switch Card52Step1 Properly ground yourself to avoid potential ESD and damage to the module.52Step2 Facing the data connection end of the CiscoSFS3504 Server Switch, pull both ejector leve...52Step3 Pull the switch card toward you and out of the chassis.52Fibre Channel Gateway Card52Installing a Fibre Channel Gateway Card53Step1 Properly ground yourself to avoid potential ESD discharge and damage to hardware.53Step2 Remove the blanking panel from the slot if it is present.53Step3 Insert the Fibre Channel gateway card completely into the gateway slot.53Figure4-3 Installing a Fibre Channel Gateway Card53Step4 Close both ejector levers simultaneously and completely.53Figure4-4 Securing the Fibre Channel Gateway Card54Step5 Type the show card all CLI command to check whether the software image in the gateway matc...54Removing a Fibre Channel Gateway Card55Step1 If possible, take the Fibre Channel gateway offline. For more details, see the shutdown co...55Step2 Properly ground yourself to avoid potential ESD discharge and damage to the Fibre Channel ...55Step3 Facing the data connection end of the CiscoSFS3504 Server Switch, pull both ejector leve...55Step4 Pull the gateway module toward you and out of the chassis.55Ethernet Gateway Card55Installing an Ethernet Gateway Card55Step1 Properly ground yourself to avoid potential ESD discharge and damage to hardware.55Step2 Remove the blanking panel from the slot if it is present.55Step3 Insert the Ethernet gateway card completely into the gateway slot.56Figure4-5 Installing an Ethernet Gateway Card56Step4 Close both ejector levers simultaneously and completely.57Figure4-6 Securing the Ethernet Gateway Card57Step5 Type the show card all CLI command to check whether the software image in the gateway matc...57Removing an Ethernet Gateway Card58Step1 If possible, take the Ethernet gateway offline. For more details, see the shutdown command...58Step2 Properly ground yourself to avoid potential ESD discharge and damage to the Ethernet gatew...58Step3 Facing the data connection end of the CiscoSFS3504 Server Switch, pull both levers of th...58Step4 Pull the gateway module toward you and out of the chassis.58Blanking Panel for Gateway Slots58Installing a Gateway Slot Blanking Panel58Step1 Properly ground yourself to avoid potential ESD discharge and damage to the hardware.58Step2 Remove the module from the slot if it is present.58Step3 Slide the wire latches of the blanking panel inwards, with your fingers, while inserting t...58Figure4-7 Installing the Blanking Panel for Gateway Card Slots59Removing a Gateway Slot Blanking Panel59Step1 Properly ground yourself to avoid potential ESD discharge and damage to the hardware.59Step2 Facing the data connection end of the CiscoSFS3504 Server Switch, slide both wire latche...59AC Power-Fan Module60Installing an AC Power-Fan Module60Step1 Ground yourself using an approved ground wrist strap.60Step2 Remove the blanking panel if one covers the slot.60Step3 Remove the AC power-fan module from any packaging.60Step4 Hold the pull handle and insert the module completely into the slot (see Figure4-8).60Figure4-8 Installing the AC Power-Fan Module61Step5 Torque the two captive screws to 5 in-lb, using a Phillips or straight-slot screwdriver (s...61Figure4-9 Securing the AC Power-Fan Module61Removing an AC Power-Fan Module62Step1 Ground yourself using an approved ground wrist strap.62Step2 Remove the power cord from the power supply.62Step3 Unfasten the two captive screws, using a Phillips or straight-slot screwdriver.62Step4 Hold the pull handle, and slide the AC power-fan module out of the chassis.62Step5 Either replace the module immediately or secure a blanking panel to the empty bay to ensur...62Blanking Panel for AC Power-Fan Module Slot62Installing a Power-Fan Module Blanking Panel62Step1 Ground yourself using an approved ground wrist strap.62Step2 Remove the blanking panel from any packaging.62Step3 Hold the blanking panel by the pull handle and completely seat it in the opening of the va...63Figure4-10 Installing the Blanking Panel in the Power-Fan Module Slot63Step4 Torque the two captive screws to 5 in-lb, using a Phillips or straight-slot screwdriver (s...63Figure4-11 Securing the Blanking Panel in the Power-Fan Module Slot63Removing a Power-Fan Module Blanking Panel64Step1 Ground yourself using an approved ground wrist strap.64Step2 Unfasten the two captive screws on the blanking panel, using a Phillips or straight-slot s...64Step3 Hold the pull handle and pull the blanking panel toward you until it completely disengages...64565CiscoSFS3504 Server Switch LEDs65InfiniBand Switch LEDs65Figure5-1 InfiniBand Switch Card, InfiniBand Switch Ports, and Management Ethernet Port Status LEDs66InfiniBand Switch Status LEDs66Table5-1 Switch Card Status LED Indicators66InfiniBand Port Status LEDs67Table5-2 InfiniBand Port Status LED Indicators67Management Ethernet Port LEDs67Table5-3 Management Ethernet Port LED Indicators67Fibre Channel Gateway LEDs68Figure5-2 Location of Fibre Channel Gateway and Fibre Channel Port LEDs68Fibre Channel Gateway Card Status LEDs69Table5-4 Fibre Channel Card Status LED Indicators69Fibre Channel Gateway Port Status LEDs69Table5-5 Fibre Channel Port Status LED Indicators69Ethernet Gateway LEDs70Figure5-3 Location of Ethernet Gateway and Ethernet Port LEDs70Ethernet Gateway Card Status LEDs70Table5-6 Ethernet Card Status LED Indicators70Ethernet Gateway Port Status LEDs71Table5-7 Ethernet Port Status LED Link Indicator71Table5-8 Ethernet Activity LED Speed Indicator71AC Power-Fan Module LEDs72Figure5-4 AC Power-Fan Module LEDs72Table5-9 AC Power-Fan Module Status LED Indicators72A75Specifications and Compliance75General Specifications75TableA-1 General Specifications75Electrical Specifications76TableA-2 Electrical Specifications76Laser Specifications76TableA-3 Laser Specifications76B77Acronyms and Abbreviations77TableB-1 List of Acronyms and Abbreviations77A79B79C79D79E79F80G80H80I80L80M81N81O81P81R81S81T82U82V82W82Größe: 6,42 MBSeiten: 82Language: EnglishHandbuch öffnen