BenutzerhandbuchInhaltsverzeichnisModel 7003M Percent Oxygen Analyzer - Operator Manual1Essential Instructions2Rosemount Analytical Inc., Process Analytic Division2Table of Contents3List of Illustrations5List of Tables6List of Drawings6Preface7Definitions7Safety Summary8Authorized Personnel8General Precautions for Handling and Storing High Pressure Gas Cylinders10Documentation11Compliances111-0 Description and Specifications131-1 Overview131-2 Priciple of Measurement131-3 Sensors131-4 Conditions Affecting Measurement14a. Gas Composition14b. Sample and Cal Gas Pressures14c. Environmental Factors141-5 Features151-6 Specifications16a. Performance16b. Physical16c. Electrical17d. Sensors172-0 Installation192-1 Unpacking192-2 Storage192-3 Analyzer Installation192-4 Sensor Installation19a. Analyzer/Sensor Jumper Configuration192-5 Electrical Connections21a. Sensor Cable22b. Power Connections22c. Current Output Connections24d. Voltage Output Connections242-6 Relay Contacts for Alarms or On/Off Controls263-0 Operation273-1 Overview273-2 Keypad Operation27a. Single and Double Keystroke29b. Display Prompts30c. Error Messages32d. Automatic Return to RUN Mode33e. Preventing Unauthorized Access33f. Sensor Equilibrium333-3 Start-Up34a. Initial Power-Up34b. System Restart35c. Automatic Restart Due to Power Failure35d. Manual Restart353-4 Run Mode36a. Display Oxygen Concentration/Sensor Temperature36b. Acknowledge Alarms36c. Access Other Modes363-5 Setup Mode37a. Security Code39b. Current Output Range - 0-20mA or 4-20mA39c. Range Endpoint Adjustments39d. Zero Offset Adjustment413-6 Alarm Mode vs. On/Off Control Mode42a. Relay Configured as Alarm42b. Relay Configured as On/Off Controller42c. Relay Contacts44d. Fail Safe Operation44e. Relay Reset Upon Fatal Error44f. Pressure Effects on Alarms44g. Setting Alarm and On/Off Controller Relays44h. Setting Alarm Setpoints44i. Setting Alarm ON and OFF Levels454-0 Calibration and Adjustments474-1 Frequency of Calibration474-2 Calibration Mode47a. Zero Calibration47b. Span Calibration47c. Pressure Compensation - Correction for Constant Pressure Differences504-3 Hold Mode514-4 Diagnostics Mode54a. Raw Signal Voltage54b. Test Current Output54c. Linearizing Current Output54d. Test Alarm Relays564-5 Adjustments and Settings565-0 Theory575-1 Principles of Operation57a. Electrochemical Theory575-2 Effects of Sample Conditions57a. Barometric Pressure57b. Humidity57c. Sample Temperature57d. Interfering Gases585-3 Circuit Descriptions58a. Signal Board58b. Power Supply Board58c. Microprocessor Board58d. Alarm Circuits586-0 Routine Servicing and Troubleshooting596-1 Routine Servicing596-2 Troubleshooting59a. Symptoms597-0 Replacement Parts617-1 Circuit Board Replacement Policy617-2 Matrix617-3 Replacement Parts - Model 7003M627-4 Replacement Parts - Sensors63a. Rechargeable Sensors63b. Disposable Sensors648-0 Return of Material658-1 Return of Material658-2 Customer Service658-3 Training65Warranty67Emerson Process Management - Worldwide68Figures12-1 Sensor Ordering Matrix202-2 Model 7003M Rear Panel Connections212-3 Power Jumpers and Fuses232-4 Current Output Connections253-1 Model 7003M Front Panel Controls and Indicators273-2 Model 7003M Operation Flow Diagram283-3 Setup Mode Flowchart383-4 Security Access Routine Flowchart403-5 Alarm Mode Flowchart433-6 Action of Alarm Relay ON and OFF Setpoints454-1 Calibration Mode and Pressure Compensation Flowchart494-2 Hold and Diagnostics Modes Flowchart53Tables1Mode/Function132-1 Sensor Cables (Part Number/Length)222-2 Analyzer Cable Connections (With/without conduit)223-1 Key Functions (How to use)293-2 Display Indicators (Indicator/Display Status/Description)293-3 Security Access Prompts and Responses (Code/Definition)303-4 Alarm Settings Prompts and Responses (Code/Definition)303-5 Calibration Prompts and Responses (Code/Definition)303-6 System Setup Prompts and Responses (Code/Definition)303-7 System Hold and Diagnostics Codes (Code/Definition)313-8 Data Displayed in Diagnostics Mode (Code/Definition)313-9 Miscellaneous Promps and Responses (Code/Definition)313-10 Power ON, Reset Diagnostics Errors - Fatal Errors (Code/Definition)323-11 Run Mode Errors - Non-Fatal Errors (Code/Definition)323-12 Signal Board Errors (Code/Definition)323-13 Microprocessor Errors That Reset The System (Code/Definition)323-14 Default Settings at Power-Up343-15 Run Mode Key Functions (Key/Display/What Happens)363-16 Setup Mode Key Functions (Key/Display/What Happens)373-17 Alarm Mode Key Functions (Key/Display/What Happens)423-18 Alarm Relay Contact Postions/Terminal Locations444-1 Calibration Mode Key Functions (Key/Display/What Happens)474-2 Composition of Dry Atmospheric Air484-3 Composition of Humid Atmospheric Air484-4 Barometric Pressure Effect on Apparent Oxygen Concentration504-5 Pressure Compensation Mode Key Functions (Key/Display/What Happens)504-6 Hold Mode Key Functions (Key/Display/What Happens)514-7 Caret Readings (Symbol/Value for/Typical Value/Adjustable - yes-no)524-8 Diagnostics Mode Key Functions (Key/Display/What Happens)54Drawings1652542 Outline and Mounting Dimensions - Panel Mount Analyzer69652543 Outline and Mounting Dimensions - Wall Mount Analyzer70652544 Outline and Mounting Dimensions - Pipe Mount Analyzer71652682 Model 7003M Pictorial Wiring Diagram72652683 Model 7003M Interconnect Diagram73652699 Model 7003M Installation Drawing74Größe: 3,01 MBSeiten: 74Language: EnglishHandbuch öffnen
BenutzerhandbuchInhaltsverzeichnisModel 7003M Percent Oxygen Analyzer - Operator Manual1Essential Instructions2Rosemount Analytical Inc., Process Analytic Division2Table of Contents3List of Illustrations5List of Tables6List of Drawings6Preface7Definitions7Safety Summary8Authorized Personnel8General Precautions for Handling and Storing High Pressure Gas Cylinders10Documentation11Compliances111-0 Description and Specifications131-1 Overview131-2 Priciple of Measurement131-3 Sensors131-4 Conditions Affecting Measurement14a. Gas Composition14b. Sample and Cal Gas Pressures14c. Environmental Factors141-5 Features151-6 Specifications16a. Performance16b. Physical16c. Electrical17d. Sensors172-0 Installation192-1 Unpacking192-2 Storage192-3 Analyzer Installation192-4 Sensor Installation19a. Analyzer/Sensor Jumper Configuration192-5 Electrical Connections21a. Sensor Cable22b. Power Connections22c. Current Output Connections24d. Voltage Output Connections242-6 Relay Contacts for Alarms or On/Off Controls263-0 Operation273-1 Overview273-2 Keypad Operation27a. Single and Double Keystroke29b. Display Prompts30c. Error Messages32d. Automatic Return to RUN Mode33e. Preventing Unauthorized Access33f. Sensor Equilibrium333-3 Start-Up34a. Initial Power-Up34b. System Restart35c. Automatic Restart Due to Power Failure35d. Manual Restart353-4 Run Mode36a. Display Oxygen Concentration/Sensor Temperature36b. Acknowledge Alarms36c. Access Other Modes363-5 Setup Mode37a. Security Code39b. Current Output Range - 0-20mA or 4-20mA39c. Range Endpoint Adjustments39d. Zero Offset Adjustment413-6 Alarm Mode vs. On/Off Control Mode42a. Relay Configured as Alarm42b. Relay Configured as On/Off Controller42c. Relay Contacts44d. Fail Safe Operation44e. Relay Reset Upon Fatal Error44f. Pressure Effects on Alarms44g. Setting Alarm and On/Off Controller Relays44h. Setting Alarm Setpoints44i. Setting Alarm ON and OFF Levels454-0 Calibration and Adjustments474-1 Frequency of Calibration474-2 Calibration Mode47a. Zero Calibration47b. Span Calibration47c. Pressure Compensation - Correction for Constant Pressure Differences504-3 Hold Mode514-4 Diagnostics Mode54a. Raw Signal Voltage54b. Test Current Output54c. Linearizing Current Output54d. Test Alarm Relays564-5 Adjustments and Settings565-0 Theory575-1 Principles of Operation57a. Electrochemical Theory575-2 Effects of Sample Conditions57a. Barometric Pressure57b. Humidity57c. Sample Temperature57d. Interfering Gases585-3 Circuit Descriptions58a. Signal Board58b. Power Supply Board58c. Microprocessor Board58d. Alarm Circuits586-0 Routine Servicing and Troubleshooting596-1 Routine Servicing596-2 Troubleshooting59a. Symptoms597-0 Replacement Parts617-1 Circuit Board Replacement Policy617-2 Matrix617-3 Replacement Parts - Model 7003M627-4 Replacement Parts - Sensors63a. Rechargeable Sensors63b. Disposable Sensors648-0 Return of Material658-1 Return of Material658-2 Customer Service658-3 Training65Warranty67Emerson Process Management - Worldwide68Figures12-1 Sensor Ordering Matrix202-2 Model 7003M Rear Panel Connections212-3 Power Jumpers and Fuses232-4 Current Output Connections253-1 Model 7003M Front Panel Controls and Indicators273-2 Model 7003M Operation Flow Diagram283-3 Setup Mode Flowchart383-4 Security Access Routine Flowchart403-5 Alarm Mode Flowchart433-6 Action of Alarm Relay ON and OFF Setpoints454-1 Calibration Mode and Pressure Compensation Flowchart494-2 Hold and Diagnostics Modes Flowchart53Tables1Mode/Function132-1 Sensor Cables (Part Number/Length)222-2 Analyzer Cable Connections (With/without conduit)223-1 Key Functions (How to use)293-2 Display Indicators (Indicator/Display Status/Description)293-3 Security Access Prompts and Responses (Code/Definition)303-4 Alarm Settings Prompts and Responses (Code/Definition)303-5 Calibration Prompts and Responses (Code/Definition)303-6 System Setup Prompts and Responses (Code/Definition)303-7 System Hold and Diagnostics Codes (Code/Definition)313-8 Data Displayed in Diagnostics Mode (Code/Definition)313-9 Miscellaneous Promps and Responses (Code/Definition)313-10 Power ON, Reset Diagnostics Errors - Fatal Errors (Code/Definition)323-11 Run Mode Errors - Non-Fatal Errors (Code/Definition)323-12 Signal Board Errors (Code/Definition)323-13 Microprocessor Errors That Reset The System (Code/Definition)323-14 Default Settings at Power-Up343-15 Run Mode Key Functions (Key/Display/What Happens)363-16 Setup Mode Key Functions (Key/Display/What Happens)373-17 Alarm Mode Key Functions (Key/Display/What Happens)423-18 Alarm Relay Contact Postions/Terminal Locations444-1 Calibration Mode Key Functions (Key/Display/What Happens)474-2 Composition of Dry Atmospheric Air484-3 Composition of Humid Atmospheric Air484-4 Barometric Pressure Effect on Apparent Oxygen Concentration504-5 Pressure Compensation Mode Key Functions (Key/Display/What Happens)504-6 Hold Mode Key Functions (Key/Display/What Happens)514-7 Caret Readings (Symbol/Value for/Typical Value/Adjustable - yes-no)524-8 Diagnostics Mode Key Functions (Key/Display/What Happens)54Drawings1652542 Outline and Mounting Dimensions - Panel Mount Analyzer69652543 Outline and Mounting Dimensions - Wall Mount Analyzer70652544 Outline and Mounting Dimensions - Pipe Mount Analyzer71652682 Model 7003M Pictorial Wiring Diagram72652683 Model 7003M Interconnect Diagram73652699 Model 7003M Installation Drawing74Größe: 3,01 MBSeiten: 74Language: EnglishHandbuch öffnen