BenutzerhandbuchInhaltsverzeichnisINTRODUCTION1DISPLAY AND KEYPAD FUNCTIONS2DISPLAY2KEYPAD3PREPARATION5INSERTING THE BATTERIES5CONDUCTIVITY ELECTRODE INFORMATION6CONNECTING THE ELECTRODE TO THE METER7ATTACHING THE ELECTRODE HOLDER TO THE METER8Inserting the electrode into the electrode holder8CONNECTING THE AC/DC ADAPTER9CONNECTING THE RS232C CABLE (ONLY FOR CON 110)9RS232C Configuration10CALIBRATION11IMPORTANT INFORMATION ON METER CALIBRATION11PREPARING THE METER FOR CALIBRATION12TEMPERATURE CALIBRATION13SELECTION OF AUTOMATIC OR MANUAL CALIBRATION14AUTOMATIC CALIBRATION (FOR CONDUCTIVITY CALIBRATION ONLY)15MANUAL CALIBRATION (FOR CONDUCTIVITY & TDS CALIBRATION)17TDS CALIBRATION18Calibrating for TDS Using Conductivity Standards & adjusting TDS factor18Setting the TDS Conversion Factor18Calibrating for TDS using TDS standards19MEASUREMENT20AUTOMATIC TEMPERATURE COMPENSATION20MANUAL TEMPERATURE COMPENSATION21Setting the manual temperature compensation value22TAKING MEASUREMENTS23Taking measurements with READY indicator selected on23Taking measurements with the Auto HOLD feature selected on23USING MANUAL RANGING FUNCTION24Selecting manual range24HOLD FUNCTION25MEMORY FUNCTION26MEMORY INPUT26MEMORY RECALL27PRINT FUNCTION (FOR CON 110 ONLY)28USING CON 110 METER WITH PRINTER OR COMPUTER28SENDING DATA TO COMPUTER OR PRINTER29Printing Current Data Manually30Print Data on Timed Interval30Print Data from Stored Memory32ADVANCED SETUP FUNCTION34ADVANCED SETUP MODE OVERVIEW36P1.0: UNIT CONFIGURATION (COF)38P1.1: Selection of READY and Auto HOLD function38P1.2: Selection of °C or °F39P1.3: Selection of Automatic or Manual Temperature Compensation40P1.4: Selection of TDS Conversion Factor41P2.0: VIEWING CALIBRATION DATA42P3.0 VIEWING ELECTRODE DATA43P4.0: AUTO OFF44P5.0: RESET TO FACTORY DEFAULTS45P5.1: Calibration Reset45P5.2: User Reset46P6.0: MEMORY CLEAR47P7.0: TEMPERATURE48P7.1: Setting the temperature coefficient48P7.2: Setting the normalisation temperature49P8.0: SELECTION OF CELL CONSTANT50P9.0: AUTOMATIC AND SINGLE POINT CALIBRATION51P9.1: Selection of Automatic or Manual Calibration51P9.2: Selection of Single or Multi Point Calibration52CYBERCOMM PORTABLE DAS (FOR CON 110 ONLY)53SYSTEM REQUIREMENTS53LOADING CYBERCOMM PORTABLE DAS53RUNNING CYBERCOMM PORTABLE59Buttons & Check-Box60Menu61Communication Settings62CAPTURING AND PRINTING DATA INTO COMPUTER USING DATA ACQUISITION63TROUBLE-SHOOTING GUIDE64ELECTRODE CARE AND MAINTENANCE65ERROR MESSAGES66TROUBLE SHOOTING67LIST OF ACCESSORIES68REPLACEMENT METER AND METER ACCESSORIES68CALIBRATION SOLUTIONS68FACTORY DEFAULT SETTINGS69CON 11 FACTORY DEFAULT SETTING69CON 110 FACTORY DEFAULT SETTING70SPECIFICATIONS71CALIBRATION TIPS73CALCULATING TDS CONVERSION FACTORS73CALCULATING TEMPERATURE COEFFICIENTS74WARRANTY75RETURN OF ITEMS75Größe: 1,2 MBSeiten: 80Language: EnglishHandbuch öffnen