BenutzerhandbuchInhaltsverzeichnisImportant Safety Information5I. Specifications6A. Icemaker61. KM-2500SWH3 (water-cooled)62. KM-2500SRH3 (remote air-cooled)7B. Condenser Unit81. URC-23F8II. General Information10A. Construction101. KM-2500SWH3 (water-cooled)102. KM-2500SRH3 (remote air-cooled)11B. Sequence of Operation121. Sequence Cycles and Shutdown12a) 1-Minute Fill Cycle12b) Initial Harvest Cycle12c) Freeze Cycle12d) Pump-Out Cycle12e) Harvest Cycle13f) Shutdown132. Sequence Flow Chart14C. Control Board151. Control Board Layout162. Features17a) Maximum Water Supply Period – 6 minutes17b) Harvest Backup Timer and Freeze Timer17c) High Temperature Safety17d) Low Water Safety17e) High Voltage and Low Voltage Cut-outs173. LED Lights and Audible Alarm Safeties184. Controls and Adjustments19a) Default Dip Switch Settings19b) Harvest Timer (S4 dip switch 1 & 2)19c) Pump-Out Timer (S4 dip switch 3 & 4)20d) Pump-Out Frequency Control (S4 dip switch 5 & 6)20e) Bin Control Selector (S4 dip switch 7)21f) Factory Use (S4 dip switch 8)21g) Freeze Timer (S4 dip switch 9 & 10)21D. Bin Control22E. Float Switch22F. Thermistor22G. Control Switch22III. Technical Information23A. Water Circuit and Refrigeration Circuit231. KM-2500SWH3 (water-cooled)232. KM-2500SRH3 (remote air-cooled)24B. Wiring Diagrams251. KM-2500SWH3 (water-cooled), KM-2500SRH3 (remote air-cooled)25C. Performance Data261. KM-2500SWH3 (water-cooled)262. KM-2500SRH3 (remote air-cooled)27IV. Service Diagnosis28A. Diagnostic Procedure28B. Control Board Check31C. Bin Control Check32D. Float Switch Check and Cleaning32E. Thermistor Check34F. Diagnostic Charts35V. Removal and Replacement of Components43A. Service for Refrigerant Lines431. Refrigerant Recovery432. Brazing443. Evacuation and Recharge (R-404A)44B. Removal and Replacement of Compressor45C. Removal and Replacement of Expansion Valve46D. Removal and Replacement of Hot Gas Valve or Liquid Line Valve47E. Removal and Replacement of Evaporator48F. Removal and Replacement of Water-Cooled Condenser49G. Removal and Replacement of Remote Air-Cooled Condenser50H. Removal and Replacement of Water Regulating Valve (water‑cooled model)51I. Adjustment of Water Regulating Valve - Water-Cooled Model52J. Removal and Replacement of Headmaster (Condensing Pressure Regulator - C.P.R.) - Remote Air-Cooled Model52K. Removal and Replacement of Thermistor53L. Removal and Replacement of Fan Motor – Remote Air-Cooled Model54M. Removal and Replacement of Inlet Water Valve54N. Removal and Replacement of Pump Motor55O. Removal and Replacement of Control Board56VI. Cleaning and Maintenance57A. Cleaning and Sanitizing Instructions571. Cleaning Procedure582. Sanitizing Procedure - Following Cleaning Procedure59B. Maintenance60C. Preparing the Icemaker for Long Storage60Größe: 1,88 MBSeiten: 61Language: EnglishHandbuch öffnen