BenutzerhandbuchInhaltsverzeichnis“Caution: Federal law restricts this device to sale or rental by or on order of a physician, or any other practitioner licensed by the law of the State in which he/she practices to use or order the use of this device.”1Operator’s Manual1HomeFill™1Oxygen Post Valve1Cylinder1HF2Post61HF2post91HF2POSTD1m WARNING2DO NOT OPERATE THIS EQUIPMENT WITHOUT FIRST READING AND UNDERSTANDING THIS MANUAL. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS,...2m warning2Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories. Accessories designed by other manufacturers have not been tested by Invacare.2c danger2DO NOT SMOKE while using this device. Keep all matches, lighted cigarettes, candles or other sources of ignition out of the room...2NOTICE2The information contained in this document is subject to change without notice.2SPECIAL NOTES 43Receiving Inspection 43Intended Use 43section 1-General Guidelines 53section 2-Features 83section 3-Typical Product3Parameters 93section 4-inspection and compressor3interface 103Cylinder Prefill Inspection 103Filling the Cylinder 133section 5-Maintenance 193section 6-Cylinder Fill Times 203Troubleshooting 203Replacement Parts - Accessories 203Limited Warranty 223SPECIAL NOTES4Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. Refer to the following table for definitions of the signal words.4Signal Word4meaning4Receiving Inspection4Remove product from package and inspect for damage. If there is any damage, DO NOT use. Contact your dealer/ Home Care equipment provider.4Intended Use4To store supplemental oxygen for use with a CGA 870 post valve compatible conserver or regulator to be used by patients who may have difficulty extracting oxygen from the air they breathe.4NOTE: Updated versions of this manual are available on www.invacare.com.4Section 1- General Guidelines5m warning5SECTION 1 - IMPORTANT SAFEGUARDS contains important information for the safe operation and use of this product. Do not use this ...5m danger5This product is not intended as a life-sustaining or life-supporting device.5m warning5Only personnel instructed and trained in the use of the HF2POST6, HF2POST9, and HF2POSTD Cylinder Assembly should operate this product.5Product contains magnetic, ferrous material that may affect the results of an MRI.5Be sure all connections are tight and leak free.5DO NOT use a liquid leak detector to test for leaks.5DO NOT autoclave.5DO NOT gas sterilize with ethylene oxide.5DO NOT clean with aromatic hydrocarbons.5m warning6DO NOT attempt to repair product.6DO NOT immerse product in any kind of liquid.6Store product in a clean area when not in use.6Only use an Invacare Corporation HF2POST6BAG or HF2POST9BAG carrying bag.6NEVER smoke in an area where oxygen is being administered.6ALWAYS confirm prescribed dose before administering to patient and monitor on a frequent basis.6DO NOT use if dirt or contaminants are present on or around cylinder, valve, product or connecting devices.6NEVER use near any type of flame or flammable/explosive substances, vapors or atmosphere.6ALWAYS follow ANSI and CGA standards for Medical Gas Products and Flowmeters (E-7) and Oxygen Handling (G-4).6The use of this device is limited to the oxygen patient. Cylinders MUST be used only by the oxygen patient and are not to be distributed to any other individual for any purpose.6DO NOT allow oil from your hands or other sources to come into contact with the cylinder fittings. These substances may become f...6m warning7NEVER oil or lubricate the cylinder fittings. NEVER use any penetrating oil or lubricant such as WD-40 or 3 in One. If connectio...7DO NOT allow cylinders to tip or fall. Secure gas cylinders so they cannot fall. Ensure cylinder is always in upright position.7DO NOT store cylinders near sources of heat or flame.7DO NOT use while sleeping without consulting your healthcare provider.7DO NOT place the unit under clothing while in use. When this product is in use a small amount of oxygen is vented. Wearing the u...7Section 2- Features8Cylinder Fill Port8FIGURE 2.1 Product Diagram8Section 3- Typical Product Parameters9HF2POST6: Weight9HF2POST6: Overall Length9HF2POST6: Diameter9HF2POST9: Weight9HF2POST9: Overall Length9HF2POST9: Diameter9HF2POSTD: Weight9HF2POSTD: Overall Length9HF2POSTD: Diameter9Section 4- inspection and compressor interface10NOTE: Refer to the HomeFill ™ Compressor Owner’s Manual for compressor operating instructions.10Cylinder Prefill Inspection10m warning10All cylinders MUST be inspected before attempting to fill; otherwise, injury or damage may occur.10NEVER smoke in an area where oxygen is being administered.10NEVER use near any type of flame or flammable/explosive substances, vapors or atmosphere.10NOTE: For this procedure, refer to FIGURE 4.1 on page 12.10The Hydrostatic Testing Date10Aluminum cylinders MUST undergo testing every five years.10m warninG10DO NOT fill cylinders that have not been tested in the past five years. Otherwise, serious personal injury may result. Contact your dealer for replacement.10External Examination11NOTE: For this procedure, refer to FIGURE 4.1 on page 12.111. Examine the outside of the cylinder for the following conditions and replace the cylinder if they exist:11. Dents or dings11. Arc burns11. Oil or grease11. Any other signs of damage that might cause a cylinder to be unacceptable or unsafe for use.112. Examine the cylinder for evidence of fire or thermal damage. Evidence includes charring or blistering of the paint, or other protective coating or heat sensitive indicator. If fire or thermal damage is found, replace the cylinder.113. Inspect the cylinder fillport for the following and replace if found:11. Debris, oil or grease11. Noticeable signs of damage11. Signs of corrosion inside the valve11. Signs of excessive heat or fire damage11FIGURE 4.1 External Examination12Checking Cylinder Pressure12m warning12NEVER use tools of any kind to connect/disconnect the cylinder and the compressor. Otherwise, severe injury and/or damage may occur.12DO NOT drop oxygen cylinders. Use two hands when handling/transporting oxygen cylinders. Otherwise, injury or damage may occur.12DO NOT use a liquid leak detector to test for leaks.12NOTE: For this procedure, refer to FIGURE 4.2 on page 14.121. Install a conserver or regulator onto the cylinder according to the device manufacturer instructions.122. Ensure toggle valve is open. Open the toggle valve by rotating counterclockwise.133. Examine the gauge on the connected conserver or regulator. Perform one of the following:13. If the cylinder pressure is less than 1500 psig, fill the cylinder. Connect the cylinder to the compressor. Refer to Filling the Cylinder on page 13.13. If the cylinder pressure is greater than 1500 psig., Do NOT attempt to fill this cylinder. It may not fill. Use cylinder as normal.13Filling the Cylinder13NOTE: For this procedure, refer to FIGURE 4.2 thru FIGURE 4.7.131. Check the cylinder pressure before attempting to fill cylinder. Refer to Checking Cylinder Pressure on page 12.132. Close the toggle valve by rotating clockwise (FIGURE 4.2).133. Remove the conserver or regulator according to the device manufacturer instructions (FIGURE 4.2).13Conserver/ Regulator14FIGURE 4.2 Component Identification144. Remove the post valve cover (located on the cylinder) and the connector fillport covers (located on the compressor) (FIGURE 4.3).14Connector Fillport Cover14FIGURE 4.3 Fillport Covers145. On the compressor unit, momentarily push DOWN on the outer ring (sleeve) of the connector fillport to reset the connector (FIGURE 4.4).14NOTE: If the outer ring (sleeve) is in the UP position (GREEN dots not visible), the connector fillport will not be able to acce...15Connector Fillport15FIGURE 4.4 Resetting Connector Fillport156. Grasp the cylinder assembly as shown in Detail “A” in FIGURE 4.5.157. Position the cylinder in the compressor cradle as shown in Detail “C” in FIGURE 4.5.158. Align the cylinder fillport with the connector fillport as shown in Detail “C” in FIGURE 4.5.159. Pull UP on the outer ring (sleeve) of the connector fillport (Detail “B”) while pushing DOWN on the cylinder assembly to couple the cylinder fillport into the connector fillport as shown in Detail “B” in FIGURE 4.5.15NOTE: The cylinder is properly connected when an audible “click” is heard.1510. Press the compressor power switch to the On () position.15NOTE: Refer to Cylinder Fill Times on page 20 for the length of time it will take to fill the cylinder.16Cylinder16FIGURE 4.5 Connecting the Cylinder to the Compressor1611. After the cylinder is full, press the compressor power switch to the Off (O) position (FIGURE 4.6).1712. Grasp the cylinder assembly (FIGURE 4.6).1713. With the other hand, grasp the outer ring (sleeve) of the connector fillport and push DOWN (FIGURE 4.6).1714. Lift up on the cylinder assembly to remove from the connector fillport (FIGURE 4.6).17Cylinder Assembly17FIGURE 4.6 Disconnecting the Cylinder from the Compressor1715. When the cylinder fillport is disconnected from the connector fillport, release the outer ring (sleeve) of the connector fillport (FIGURE 4.6).1716. Remove the cylinder from the compressor cradle (FIGURE 4.6).17m warning18The fillport cover on the connector fillport and the post valve fillport MUST be replaced after filling and whenever not in use. If either of the fillport covers are missing contact your healthcare provider before using.1817. Place the fillport covers onto the connector fillport (located on the compressor) and post valve fillport (located on the cylinder) (FIGURE 4.7).1818. Install a CGA870 post valve compatible conserver or regulator according to the manufacturer’s instructions.1819. Open the toggle valve by turning counterclockwise and examine the conserver or regulator gauge to ensure cylinder is full (needle pointing into GREEN area). If the cylinder is not full, perform the following:18. Repeat Filling the Cylinder on page 13.18. If cylinder is not full after second attempt to fill, contact the provider.18Connector Fillport Cover18FIGURE 4.7 Connector Fillport18Section 5- Maintenance191. After each use, clean exterior of the product with a dry, lint free cloth only.192. Store product in a clean area free from grease, oil, and other sources of contamination.19caution19DO NOT use cleaning solutions.19DO NOT immerse product in any kind of liquid.19All repairs MUST be done by Invacare Corporation.19Section 6- Cylinder Fill Times20NOTE: All filling times are approximate and may vary on environmental conditions.20*20Cylinder Filling Times20Concentrator Flow Rate to Patient:20(Platinum 5 up to 3 L/min. and Platinum 10 up to 5 L/min)20Troubleshooting20If post valve cylinder fails to function, try the following solutions. If problem cannot be corrected, consult your dealer/home care equipment provider.20problem20possible cause20solution20Replacement Parts - Accessories20HF2POST6BAG or HF2POST9BAG Carrying Bag.20Notes21Part No 114811424Rev B - 9/0724Limited Warranty22PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975.22This warranty is extended only to the original purchaser/user of our products.22This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state.22Invacare warrants this product to be free from defects in materials and workmanship for a period of three years from date of pur...22For warranty service, please contact the Invacare service department during normal business hours at the toll-free telephone number identified on the back cover of this manual.22Upon receiving notice of an alleged defect in a product, Invacare will issue a serialized return authorization. It shall be the ...22LIMITATIONS AND EXCLUSIONS: THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REM...23THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES WHATSOEVER, WHETHER EXPRESSED OR IMPLIED, INCLUD...23SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGE, OR LIMITATION OF HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE EXCLUSION AND LIMITATION MAY NOT BE APPLICABLE.23THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE/PROVINCIAL LAWS AND REQUIREMENTS.23Größe: 642 KBSeiten: 24Language: EnglishHandbuch öffnen