BenutzerhandbuchInhaltsverzeichnisSAFETY MESSAGES2TABLE OF CONTENTS3LIST OF FIGURES7LIST OF TABLES8INTRODUCTION9Preface9Warranty9Principle Of Operation10Interferent Rejection12Specifications13Noise (PPB RMS)14Lower Detectable Limit (LDL) PPB14Zero Drift (PPB)14Span Drift14Linearity14Lag Time14Rise And Fall Times14Temperature Range14Humidity Range14Flow Rates15Power15Weight15Installation And Overview15Electrical And Pneumatic Connections22Electrical Connections22RS-23222Pneumatic System24Exhaust Connections (See Figure 1-5)24Output Flow Adjustment24Operation Verification28Final Test And Calibration Values29Options30Rack Mount With Slides30Status Outputs30OPERATION31Key Features31O3 Readout31O3 Analog Output31E2 ROM Backup Of Software Configuration31Adaptive Filter31Data Acquisition32RS-232 Interface32Password Protection32Front Panel34Front Panel Display34Programmable Pushbuttons37Status LEDs39CALIBRATION41Manual Zero Air Supply41Manual O3 Generation41Automatic Zero/Span (or Multipoint) Check42Manual Zero/Span (or Multi-Point) Check42Summary Of Front Panel Calibration Controls43Photometer Calibration43Remote Zero/Span Check (Contact Closure)44Remote Zero/Span Check Or Adjustment (RS-232)45Hold Off45SETUP MODE47Setup Mode Operation47Setting Automatic Multipoint (ASEQ) Check47Setting Automatic Zero/Span Duration47Examining The Ozone Formula Slope And Offset48Setting the O3 Generation Mode49BNCH Mode49REF Mode49CNST Mode49Setting The Time-Of-Day49Setting The Date49Adjusting The Clock Speed50Setting The O3 Concentration Range50Setting The Analog Output Offset50Setting The RS-232 Baud Rate50Setting The Analyzer I.D.51Disabling The Calibration Password51Setting The Fault LED Timeout51Software Configuration52Summary Of Setup Variables52DIAGNOSTICS55Test Measurements55Diagnostic Tests55D/A Output56HANDLING WARNINGS57RS-232 COMMUNICATIONS59DAS Reporting60Warnings61Status/Control62Diagnostics64Test Measurements65Viewing And Modifying Variables66ADJUSTMENTS69Power Supply Board Adjustment69Box Temperature Limits69A/D - D/A Calibration Procedure71Output Voltage Range Changes72Flow Readout Adjustment72DC Power Supply74CPU74Status Lines75UV Lamp Power Supply Adjustment75Ozone Generator Lamp Setup76Ozone Generator Calibration77Dark Current Signal Adjust Procedure77Bench Feedback Option78TROUBLESHOOTING79Overview79Troubleshooting Fundamental Calibrator Operation79Checking The Power Sub-Systems80Checking The CPU And Display81Checking The Keyboard81Troubleshooting Using Warning Messages81Troubleshooting Using Test Function Values83Troubleshooting Dynamic Problems84Noisy Or Unstable Readings At Zero85Noisy, Unstable, Or Non-Linear Span Readings85Slow Response To Changes In Concentration85Analog Outputs Do Not Agree With Front Panel Readings86Cannot Zero86Cannot Span86Troubleshooting Individual Sub-Assemblies And Components87Troubleshooting Flow Problems87Troubleshooting Temperature Problems88Checking The V/F Card89Checking The DC Power Supply Board91Checking The Pneumatic Sensor Board92Checking The Source Lamp And Detector92Checking Main Switching Valve94Checking The Lamp Power Supply94Warranty/Repair Questionnaire96ROUTINE MAINTENANCE97Maintenance Schedule97Leak Checking98Cleaning Of Sample Cell98Changing The Prom99MODEL 401 SPARE PARTS AND EXPENDABLES KITS101Spare Parts For CE Mark Units101Spare Parts For Non-CE Mark Units103LIST OF AVAILABLE MODEL 401 OPTIONS105RECOMMENDED ZERO AIR SYSTEM107REFERENCES109SOFTWARE MENU TREES111ELECTRICAL SCHEMATIC INDEX113Größe: 1,07 MBSeiten: 114Language: EnglishHandbuch öffnen