3M 78-8135-4385-3-A User Manual

Page of 28
78-8135-4385-3-A
 
7
4.4 
Insert the connector into the hot melt connector 
holder.
4.5 
Place the load adapter, with slot aligned with handle, 
into an available port in the oven. 
IMPORTANT: Do not place connector in a hot load 
adapter. This may cause adhesive to flow to the 
outside of the ferrule. Load adapter should be at room 
temperature when connector is inserted.
4.6 
The 3M
 LC Hot Melt Connector should be in the 
oven for at least 75 seconds. The connector should not 
be in the oven longer than 5 minutes.
4.7 
Place the heat shrink fixture in an available port in the 
oven. 
Note: This step is only necessary for use with the 
1.6–2.0 mm jacketed LC hot melt connector.