Zebra Technologies P1058563-003 User Manual
79
WebLink Set/Get/Do Commands
weblink.ip.conn[1|2].test.location
10/31/13
P1058563-003
Example •
The test connection can assist the user in several ways/scenarios:
1.
If the
test.test_on
value is set to
"failure"
, any time the main weblink
(
conn[1|2].location
) connection fails to connect then the
test.location
URL will be
used. In this situation, an attempt will be made to contact the remote URL in
test.location
, using authentication and proxy configuration that is specified by the main
connection.
2.
If the
test.test_on
value is set to
"interval"
an attempt will be made to contact the
remote URL in
test.location
every
test.retry_interval
seconds, using authentication
and proxy configuration that is specified by the main connection.
3.
If the
test.test_on
value is set to
"both"
, then scenario 1 and 2 will both occur. This is
useful for users who will use an HTTP connection to move through their firewall - and
thereafter frequently refresh the connection to indicate to their firewall that there is still
activity for the purpose of keeping the connection alive.
thereafter frequently refresh the connection to indicate to their firewall that there is still
activity for the purpose of keeping the connection alive.