Emerson 2200S User Manual

Page of 158
Configuration and Use Manual
59
Configuring Operational Parameters
Op
eratio
n
App
e
ndi
ces
Mai
n
tenan
c
e and
 T
roub
le
sh
oo
tin
g
Com
m
is
si
on
in
g
5.5
Configuring device parameters
The device parameters are used to describe the flowmeter as a system. Device parameters are listed 
and defined in Table 5-6. 
Note: The HART device ID, which is displayed in some menus, can be set only once, and is usually set at the 
factory to the device serial number. If the HART device ID has not been set, its value is 0. On a multidrop 
network, the HART device ID must be a unique value.
Configuration
To configure device parameters:
Using the Communicator, select 
Detailed Setup > Device Information
.
Using ProLink II, click 
ProLink > Configuration > Device
.
Note: You cannot configure device parameters with the display.
If you are entering a date:
With ProLink II, use the left and right arrows at the top of the calendar to select the year and 
month, then click on a date.
With a Communicator, enter a value in the form mm/dd/yyyy.
Table 5-6
Device settings
Parameter
Description
Descriptor
Any user-supplied description. Not used in transmitter processing, and not required.
Maximum length: 16 characters.
Message
Any user-supplied message. Not used in transmitter processing, and not required.
Maximum length: 32 characters.
Date
Any user-selected date. Not used in transmitter processing, and not required.