Daniel 3410 Series Ultrasonic Gas Flow Meter Installation Manual
Section 1: Introduction
3-9000-759 Rev D
June 2014
Daniel 3410 Series meter design
 7
Procedure
1.
From the right panel under Quick Links, click the MeterLink Registration and Download 
link.
2.
Click the Order Now  button to complete the Online registration form. 
3.
Click Next  to go to the order confirmation page. 
4.
Click Complete Order. 
You will receive a conformation e-mail with a hyperlink directing you to the download 
site. Click the link provided.
5.
Click Save. 
Refer to the Daniel MeterLink Software for Gas and Liquid Ultrasonic Meters Quick Start Manual 
(P/N 3-9000-763) for installation instructions and setup for initial communications. You may 
download the manual from the Daniel MeterLink web page:
1.5
Daniel 3410 Series meter design
Daniel 3410 Series Gas Ultrasonic Flow Meters are designed to accurately measure products in 
applications where reliable performance is critical, by measuring the difference in signal transit 
time with and against the flow across one or more measurement path(s). A signal transmitted in 
the flow direction travels faster than one transmitted against the flow direction. Each 
measurement path is defined by a transducer pair in which each transducer alternately acts as 
transmitter and receiver. The meter uses transit time measurements and transducer location 
information to calculate the mean velocity.