Daniel 3410 Series Ultrasonic Gas Flow Meter Installation Manual
Section 2: Mechanical installation
3-9000-759 Rev D
June 2014
Use of appropriate safety engineered swivel hoist rings in meter end flanges
 
39
What size safety engineered swivel hoist ring do you need?
To determine the size of the hoist rings required for your meter, use the appropriate table below. 
Look down the column that matches the ANSI rating of your meter. Find the row that contains 
your meter size. Follow the row to the end to find the appropriate hoist ring part number.
 
 
   
Table 2-2  Hoist Ring Lookup Table for Daniel 3414 Gas Meters
1
1.  
4” to 6” 45 degree meters and 8” to 36” 60 degree meters
.
ANSI 300
ANSI 600
ANSI 900
ANSI 1500
Daniel Part Number
4” to 10”
4” to 8”
4” to 8”
4” to 6”
1-504-90-091
12” to 18”
10” to 16”
10” to 12”
8” to 10”
1-504-90-092
20” to 24”
18” to 20”
16” to 20”
12”
1-504-90-093
30” to 36”
24” to 30”
24”
16” to 20”
1-504-90-094
 
36”
30" to 36”
24" to 36”
1-504-90-095
Table 2-3  Hoist Ring Lookup Table for Daniel 3411 or 3412 Gas Meters
ANSI 300
ANSI 600
ANSI 900
ANSI 1500
Daniel Part Number
4” to 10”
4” to 8”
4” to 8”
4” to 6”
1-504-90-091
12” to 18”
10” to 16”
10” to 12”
8” to 10”
1-504-90-092
20” to 24”
18” to 20”
16” to 20”
12”
1-504-90-093
30” to 36”
24” to 30”
24”
16” to 20”
1-504-90-094
 
36”
30" to 36”
24" to 36”
1-504-90-095