Section 4: Configuration
3-9000-759 Rev D
June 2014
Field Setup Wizard
 79
Note: 
When connected to a meter with the local display option, reverse flow 
direction is indicated with a minus sign (negative) before the value(s) shown on 
the local display.
Display units:
The Meter volume units displayed are either U.S. Customary or Metric. To modify the Display 
Units, configure the Meter units system in the Field Setup Wizard — General Page. 
U.S. Customary volume unit selections are:
Cubic feet
Thousand cubic feet
Metric volume unit selections are:
Cubic meters
Display units preceded by a plus or minus sign indicate forward and reverse flow 
direction, as shown in the table below.\
The local display Flow rate time units are modifiable by selecting the drop-down arrow 
and clicking the time unit in the list box.
Valid flow rate time units selections are:
second
hour
day
KFCT1 — Frequency 1 K-factor
CF  – Cubic Feet
CM  –Cubic Meters
MCF  – Thousand Cubic Feet
MCM  –Thousand Cubic Meters
FRQ2A — Frequency channel 2A
HZ  – Hertz
FRQ2B — Frequency channel 2B
HZ  – Hertz
KFCT2 — Frequency 2 K-factor
CF  – Cubic Feet
CM  –Cubic Meters
MCF  – Thousand Cubic Feet
MCM  –Thousand Cubic Meters
AO1 — Analog Output 1 current
MA  –
 Milliamperes
AO2 — Analog Output 2 current
MA  –
 Milliamperes
Table 4-1  Local display labels, descriptions and valid units
Local display labels, descriptions and valid units