Panasonic FV-05-11VKSL1 User Manual

Page of 12
3
Do  not  install  this  ventilating  fan  where  interior  room  temperature  may 
exceed  104°F(40°C).
Make  sure  that  the  electric  service  supply  voltage  is  AC  120V,  60Hz.
Follow  all  local  electrical  and  safety  codes,  as  well  as  the  National 
Electrical  Code  (NEC)  and  the  Occupation  Safety  and  Health  Act  (OSHA).
Always  disconnect  the  power  source  before  working  on  or  near  the  fan, 
motor,  light  fixture  or  junction  box. 
Protect  the  supply  wiring  from  sharp  edges,  oil,  grease,  hot  surfaces,
chemicals  or  other  objects.
Do  not  kink  the  supply  wiring.
Provide  make  up  air  for  proper  ventilation.
For  general  ventilating  use  only.  Do  not  use  to  exhaust  hazardous  or 
explosive  materials  and  vapors.
Not  for  use  in  cooking  area.  (Fig.B)
The  special-purpose  or  dedicated  parts,  such  as  mounting
fixtures,  must  be  used  if  such  parts  are  provided.
Do  not  install  the  unit  where  ducts  are  configured  as  shown 
in  Fig.A.
CAUTION
Ceiling  joist  must  be  subjected  to  static  load  more  than  five  times  the  weight  of  the  product.
Do  not  install  with  a  method  which  is  not  approved  in  the  instructions.
WARNING
This  product  must  be  properly  grounded.
Do  not  use  this  fan  with  any  solid-state  speed  control  device.  Solid  state  controls  may  cause
harmonic  distortion  which  can  cause  motor  humming  noise.
When  this  product  is  no  longer  being  operated,  please  remove  the  product  to  prevent  the 
possibility  of  falling.
GENERAL SAFETY INFORMATION CONTINUED
Prohibited
Prohibited
Prohibited
Prohibited
Floor
45
45
Cooking
equipment
(Cooking area)
Do not install above or
inside this area
Adaptor
Fig. B
Spot and Continuous Ventilation:   These fans are designed to run continuously ensuring a healthy
environment at low CFM levels 24 hours a day. By utilizing the optional CustomVent Multi-Speed module
the fans are built to run continuously at a pre-set lower level (FV-05-11VKSL1 and FV-05-11VKL1: 0, 30, 
40, 50, 60, 70, 80, 90, 100 CFM; FV-11-15VKL1: 0, 50, 60, 70, 80, 90, 100, 110, 120 CFM). The setting is 
dependent on the size of the house and the individual wishes of the homeowner. It is crucial that the 
installer pre-set the lower setting during the installation. Please refer to the chart below and the 
switch indication on page 6. 
PLEASE READ PRIOR TO INSTALLING THIS FAN