Example of system configuration
$
When the distance between the ROP and the pan/tilt control panel is more than 10 meters
The distance between the ROP and the pan/tilt control panel can be extended up to a maximum of about 1000 meters on the
following condition using the provided cable (refer following specifications) and/or equivalent cables. (Prepare the cables of
required length.)
• Up to 50 meters:
Use the recommended AC adaptor for the power supply of the pan/tilt control panel.
• More than 50 meters: Supply DC 12V to the ROP and the pan/tilt control panel from the recommended AC adaptor. 
In this case, it is not necessary to connect +12V IN.
Specifications for provided cable
Ferrite core
Ferrite core
Use the twist pair cables.
Connector used
Japan Aviation Electronics Industry, Ltd.
Connector: D02-29PF-N-F0
Contact:
D02-22-26P-PKG100
(For AWG 26 to 28)
Case:
DA-C4-J10
Connector used
Japan Aviation Electronics Industry, Ltd.
Connector: D02-29SF-N-F0
Contact:
D02-22-26S-PKG100
(For AWG 26 to 28)
Case:
DA-C4-J10
Shield